Conference Abstracts

All Abstracts were presented at the Groundwater Conferences

Displaying 101 - 150 of 795 results
Title Presenter Name Presenter Surname Area Conference year Sort descending Keywords

Abstract

A new mining site situated near Kolwezi in the Democratic Republic of the Congo plans to develop a pit in phases over a period of six years. The mine requires dewatering volume estimates of the pit as well as a constant water supply to the plant. Hydrogeologic data available at the site during the scoping phase was limited to a few water level measurements and blowout yields from only five hydrological boreholes. Hydraulic properties from reports at neighbouring sites were extrapolated to the geological units at the site. The depth to water level at the site is about 20 m, with a planned final pit depth of approximately 180 m below surface.

Based on the limited data available an analytical approach to estimate the inflow into the mine was adopted. Analytical calculations proposed by Marinelli and Niccoli (2000) were used to estimate the inflow into the Pumpi mine pits. The analytical calculations consider recharge, depth of mining vertical and horizontal hydraulic conductivities. Drawdown evolution of pit dewatering are obtained by using different mining depths at different mine stages. The output results from the analytical calculations are the maximum extent of influence of the pit as well as the volume of water inflow into the pit. Limitations of the analytical equations are that they, amongst others, cannot consider complex boundaries.

Drilling and pump testing to obtain local hydraulic properties and boundary conditions are planned during the first quarter of 2013. The numerical model will be set up after the drilling and pumping tests, using the new data for calibration. The numerical model will contain as much of the physical layer definitions and potential internal boundaries as possible with model boundaries incorporated along  far  field  fault  zones  and  hydraulic  boundaries.  The  numerical model  should  improve the reliability of estimates of pit inflow and water supply to the plant.

The results between the analytical and numerical approaches can then be compared to improve future dewatering estimates with limited data. It is expected that the reliability of the analytical predictions will reduce after year 4, where the role of boundaries are expected to influence the drawdowns and related flow towards the pit.

Abstract

The significance of a reliable groundwater resource assessment is of growing importance as water resources are stretched to accommodate the growing population. An essential component of a groundwater resource assessment is the quantification of surface water–groundwater interaction. The  insufficient  amount  of  data  in  South  Africa  and  the  apparent  lack  of  accuracy  of  current estimates of the groundwater component of baseflow lead to the investigation of a new method. This applicability of this new approach, the Mixing Cell Model (MCM), to quantify the groundwater contribution to baseflow is examined to assess whether the method would be of use in further groundwater resource assessments. The MCM simultaneously solves water and solute mass balance equations  to  determine  unknown  inflows  to  a  system,  in  this  application  the  groundwater component of baseflow. The incorporation of water quality data into the estimation of the surface water–groundwater  interaction  increases the  use of  available  data,  and  thus has  the  ability to increase the confidence in the estimation process. The mixing cell model is applied to datasets from the surface water–groundwater interaction test site developed by the University of the Free State, in addition to data collected along the middle Modder River during a fieldwork survey. The MCM is subsequently applied to a set of quaternary catchments in the Limpopo Province for which there are available calibrated estimates of the groundwater component of baseflow for the Sami and Hughes models. The MCM is further applied to the semi-arid quaternary catchment D73F to assess the applicability of the mathematically-based MCM in a flow system within a regionally-defined zero groundwater  baseflow  zone.  The  results  indicate  that  the  MCM  can  reliably  estimate  the groundwater component of baseflow to a river when sufficient data are available. Use of the MCM has  the  potential  to  evaluate  as  well  as  increase  the  confidence  of  currently  determined groundwater baseflow volumes in South Africa, which will in turn ensure the responsible and sustainable use of the countries water resources.

Abstract

With increasing focus on wasted expenditure within local government and recent media reports on the money spent on poor quality service, it is becoming progressively important for those in a position of engaging consultants, either for groundwater supply or environmental work, to have confidence in the company or person they have employed. This paper focuses on how to assess consultants  before   they   walk  through   the  door  based   on   qualifications,   CVs,   professional registrations and previous work experience. It goes through the project lifestyle, explaining in a non- technical fashion the different processes involved in a groundwater supply or groundwater contamination assessment and provide simple indicators of good practice that should be evident in the   consultant's   work.   Topics   covered   include   assessing   proposals,   gathering   background information, health and safety, appointing sub-contractors, data quality, the use of appropriate published procedural guidelines, the use of relevant quality guidelines and what deliverables should be provided. 

Abstract

In recent years there is an increased awareness of hydrocarbon contamination in South Africa, and the need for remediating sites affected by these contaminants. Hydrocarbon contamination of groundwater can be caused by a large variety of activities at industrial, mining or residential areas. Once these contaminants are discovered in groundwater where it poses risks to human health and/or the environment, remediation is often required. Remediation of groundwater has become a booming industry for groundwater practitioners and often there is an attitude of more sophisticated and expensive solutions are better. This paper will show that this attitude is not always the best solution, but rather recommend an approach where a combination of low cost/low maintenance system need to be investigated and applied to reach clean-up goals. Determination of natural attenuation potential and on-going monitoring forms an integral part of this type of solution.

Abstract

Most of the 14 651 km2 Hwange National Park in Zimbabwe is on monotonous Aeolian sands of the Kalahari Basin, with endorheic drainage. The large game populations of the park are sustained by seasonal accumulations of water in grassy pan depressions and year-round supply of groundwater to pans (except in the northwest where there are rivers and dams). Some of this is from natural seeps, such as at the Shakwanki, Nehimba and Ngweshla Pans, but most are supplied from boreholes. Game animals show clear preferences for some pans over others and it has long been speculated by wildlife managers that there is a nutritional or taste basis for this discrimination. In this preliminary study, the location, host geology and sub-Kalahari lithologies of the pans are compared with the frequency of use by game animals. Results show that the pans that are most frequented by game are hosted in fossil drainage channels, with limestone horizons (calcrete) developed within the Kalahari Sands. Many popular pans are also found on Kalahari Sand overlying the granitic rocks and the meta- sedimentary Malaputese Formation of the Kamativi–Dete Inlier. This can be related to sodium and potassium enrichment.

Abstract

Only 40% of all the available groundwater resources are developed in South Africa and the development of surface water are becoming more costly and challenging. The Minister of Water and Environmental Affairs acknowledge this and identified the need to increase the use of groundwater as one of the interventions to address the increasing water requirement of towns and communities. Over the last seven years the Department of Water Affairs developed many reconciliation strategies for the area of water management, the big metro municipalities and for the smaller towns and villages in South Africa. The reconciliation strategies entails, among other things, sustainable ways to source additional water supplies for the selected towns/metro’s or villages. 

Groundwater played a major role in the recommended interventions. The challenges are now the implementation of the groundwater schemes and sustainable management of the groundwater resources. Or differently put: the balancing act between selling of groundwater and the prevention of over-abstraction. The bankability of regional schemes, the credibility of groundwater as a bulk scheme source, poor management of boreholes/well-fields, institutional responsibility, acceptable quality and treatment of groundwater, still challenge the use of groundwater development. Groundwater need to play its role in addressing the future water needs of South Africa, or can it?

Abstract

Characterisation of fracture positions is important when dealing with groundwater monitoring, protection and management. Fractures are often good conduits for water and contaminants, leading to  high  flow  velocities  and  the  fast  spread  of  contaminants  in  these  conduits.  Best  practice guidelines related to groundwater sampling suggest that specific depth sampling with specialised bailers or low flow purging are the preferred methodologies to characterise a pollution source. These methods require knowledge about the fracture positions and, more importantly, flow zones in the boreholes. Down-the-hole geophysical and flow logging are expensive, complicated and time consuming. Not all fracture zones identified with geophysical logging seem to contribute to flow through   the   borehole.   An   efficient   and   cost-effective   methodology   is   required   for   the characterisation of position and flow in individual fractures. This research reviewed the use of Fluid Electrical Conductivity (FEC) logging to assist with the development of a monitoring protocol. FEC logging  proved  to  be  beneficial  as  it  provided  individual  fracture  positions,  fracture  yields  and vertical groundwater flow directions. FEC logging proved to be fast, cost-effective and practical in deep boreholes. The technique allows the development of a site-specific sampling protocol. The information so obtained assists with the identification of the appropriate sampling depths during monitoring.

Abstract

Work is being conducted in Limpopo province following a large volume release of petroleum hydrocarbons that took place from a leaking underground pipeline, resulting in significant groundwater contamination. This is considered to be the largest petroleum hydrocarbon release recorded to date in South Africa. The leak took place for 15 years before it was discovered 13 years ago in 2000. From the pressure tests that were performed, 10-15 ML of A-1 Jet fuel is considered to have  been  released  to  the  subsurface.  Product  bailing was  the  first method  employed  for  the recovery of the free product, and was later replaced with a P&T system which was considered to be more effective.

The village located about 6 km to the north of the spillage depends mostly on groundwater. This paper presents a progress update of works that have been conducted in support of developing a conceptual model which aims to determine the areal extent of the plume.

Abstract

The aim of this study was to determine the geohydrological status of the aquifer within the boundaries of the Vanrhynsdorp Water User Association with emphasis on the central catchment, E33F. This will assist the Department of Water Affairs with the introduction of compulsory groundwater-use licensing and empowerment of the Vanrhynsdorp Water User Association to manage the resource. In this study emphasis was given to the determination of the water balance and  groundwater  reserve  of  the  central  catchment  and  the  designing  of  a  representative groundwater monitoring network. A literature study of five projects conducted since 1978 was done. Comparisons were made between the data and results of these studies. All the historical data from these studies, as well as the data from the current monitoring programme up until December 2012, were put together and analysed. A conceptual model and groundwater reserve determination, as well as a representative monitoring network, were produced. The study showed a general decline in groundwater levels over a 34-year period. It also showed an increase in rainfall over the last 20 years. Based on the reserve determination and the declining groundwater level in spite of increased rainfall and thus recharge, it was concluded that over-abstraction of groundwater in the study area is taking place. It is recommended that compulsory licensing should be put in place as soon as possible and  that  no  additional  groundwater-use  licences  should  be  granted  in  the  study  area.  The installation  of  flow  meters  on  all  production  boreholes  should  be  stipulated  in  the  licensing condition. This will assist the monitoring and regulation of groundwater abstraction volumes.

Abstract

Quantification of hydrological processes is required for many projects related to potential groundwater recharge. Thus, investigation on various hydrogeologic conditions is paramount. Changes of climate can affect the hydrological cycle by altering groundwater recharge. As a result, an understanding of the hydrological conditions is essential to make sensible predictions of the possible groundwater recharge. Thus WetSpass, which yields spatially varying groundwater recharge using hydrological inputs, can be used together with a geographical information system to quantify the environmentally acceptable flow regime of the catchment area. This paper presents an overview on the use of WetSpass in combination with GIS on quantification of groundwater potential which will assist to sustainable groundwater development in the catchment area. Previous applications are presented.

Abstract

This paper follows on current research taking place in the Springbok Flats Basin focusing on Carbon Dioxide Geological Sequestration within coal seams. The research, commissioned by ESKOM, began in 2012 and has a primary aim of producing a hydrogeological risk assessment for carbon dioxide geological sequestration operations scheduled for national pilot testing within the basin. One of the fundamental tools used in the assessment has been finite element mesh modeling. A 3D finite element mesh model of the study area, that has 11307 nodes, has been generated using FEFLOW algorithms. Portions in the study area without linear and point physical features have been modeled with the Advancing Front Algorithm, while the Grid Builder Algorithm has been used to model portions with linear and point features. This paper has investigated the node angle accuracy and precision of the mesh model by generating a map of the maximum interior angle of triangles. Approximately 70 % of the triangles have equilateral angles, while the remainder triangles have obtuse angles. The majority of the equilateral triangles occur within the portions modeled with the Advancing Front Algorithm. Half of the obtuse triangles have been refined to equilateral triangles with the FEFLOW refinement tools while the other half has been refined manually with the node digitizing features. FEM models perform better with dense triangle matrices with equilateral angles, as they influence the accuracy of the FEM.

Abstract

POSTER Since June 2010 and still ongoing today, the Lower Orange River Valley has experienced over a 1168 tremors(a) and earthquakes in the vicinity of Augrabies. Of these 1168 tremors, 71 quakes registered above 3 on the Richter scale and on 18 December 2011, the area was struck with an earthquake that registered 5 on the Richter scale. Four thermal springs are also located near this earthquake zone and the temperature of the water have a range of between 38?C -46.6?C, according to Kent LE. (1949/1969). 25?C is the division between thermal and non-thermal waters and the thermal gradient for the Riemvasmaak area(b) is 24?C, clearly indicating that the four springs are thermal when looking at the temperature difference. The Department of Water Affairs has been monitoring these springs monthly since 2011 and has been taking field measurements and chemical analyses. The aim of this study is a) to see if the tremors and earthquakes have an effect on the chemistry of the thermal springs, b) to create a data set for the thermal springs, as these springs was recorded and mentioned in Kent LE. reports of 1949 and 1969 but no samples were collected and analysed, c) to see if the water source for the groundwater in the area and the thermal springs are connected and d) to see if the recent floods may have had an influence on the earthquake zone seeing as the Orange River runs through the zone. The following sources are used to describe the earthquakes and water quality: (a) Earthquake data from the Council of Geosciene (b) ZQM data on NGA temp range between 21-28?C depending on the season with 24?C being the mean.

Abstract

The redox state of groundwater is an important variable for determining the solubility and mobility of elements which can occur in different redox states at earth surface conditions, such as Fe, Mn, Cr, As, U, N, S, V etc. Eh-pH diagrams are potentially invaluable for understanding and predicting the behaviour of these redox species yet, unlike pH, redox is seldom a routine field parameter due to the difficulties in measurement and interpretation.
This paper discusses the potential use and limitations of field measurements of the redox state of groundwater with specific reference to the geochemical behaviour of dissolved iron in the Table Mountain Group (TMG) aquifer. As part of an investigation into iron cycling within the TMG aquifer, the redox state of groundwater was estimated through three different methods, namely direct in-situ measurement of Eh, direct measurement of DO and calculation from iron speciation in groundwater. Comparison of the results from the three methods highlights the potential value of collecting redox data, but also the complexity of controls on redox potential. The redox measurements allowed the determination of the controlling reactions on iron mobility within the TMG, but only by using the iron speciation method to calibrate the in-situ values and thereby identify which redox pair was controlling redox equilibrium. As this requires measurement of redox ion pairs in solution, it is unlikely to become a routine method for redox assessment, unless the specific redox state of an element is critical in understanding its mobility. For the majority of groundwater site investigations, measurement of the dissolved oxygen content of groundwater is probably sufficient as a first pass.

Abstract

POSTER Vanwyksvlei had always experienced problems with water supply and quality of drinking water. The town relies on 6 boreholes to supply the town with drinking water. Since 2011 the town was told not to use the water that was supplied from the borehole called Soutgat. This meant that the town could now rely only on the water being supplied from the other 5 boreholes.From 2011 till present the town has experienced a lot of problems regarding water supply, due to the fact that the Soutgat could not be used anymore. Extra stress was put on the other boreholes and these were pumped almost dry. The two aquifers are currently failing and monitoring data since 2009 shows that the water levels of the town are decreasing. Due to low rainfall, recharge to the boreholes are much lower, which exacerbates the problem. This poster will examine the effectiveness of using the Blue Drop system in small towns with limited water supply, at the hand of a case study of Vanwyksvlei. This review will take into account factors such as the point at which water quality is tested in the water supply system, the type of water treatment available for the town and a review the usefulness of certain standards in the Blue Drop system which may indicate failure of supply sources.

Abstract

Edible vegetable oil (EVO) substrates have been successfully used to stimulate the in situ anaerobic biodegradation of groundwater contaminated chlorinated solvents as well as numerous other anaerobically biodegradable contaminants like nitrates and perchlorates at a many commercial, industrial and military sites throughout the United States of America and Europe. EVO substrates are classified as a slow release fluid substrate, and comprise of food grade vegetable oil such as canola or soya bean oil. The EVO substrate serves as an easily biodegradable source of carbon (energy) used to create a geochemically favorable environment for the anaerobic microbial communities to degrade specific contaminants of concern. EVO substrate's can either be introduced into the subsurface environment as pure oil, in the form of light non aqueous phase or as an oil/water emulsion. The emulsified vegetable oil substrates holds several benefits over non-emulsified vegetable oil as the fine oil droplet size of the commercially manufactured emulsified oils can more easily penetrate the heterogeneous pore and fracture spaces of the aquifer matrix. The use of this technology to stimulate in situ biodegradation of groundwater contaminants is still relatively unknown in South Africa. This paper will give an overview of the EVO technology and its application, specifically looking at the advantages of using this relatively inexpensive, innocuous substrate based technology to remediate contaminated groundwater within fractured rock environments commonly encountered in South Africa. {List only- not presented}

Abstract

South Africa is facing a water supply crisis caused by a combination of low rainfall, high evaporation rates, and a growing population whose geographical demands for water do not conform to the distribution of exploitable water supplies. This situation is particularly critical in the river systems comprising the Limpopo River basin where every tributary river has been exploited to the limits possible by conventional engineering approaches. These attempts to meet society's demands for water for domestic, irrigation, mining and industrial uses have caused a progressive deterioration of the water resources as well as the aquatic ecosystems in these rivers. In addition to the pressure exerted by scarce water resources and deteriorating water quality, South Africa is facing a critical shortage of electrical power. There is an urgent need to address the country's electricity shortage through the building of new coal mines and coal fired power and the Waterberg area has been identified for these purposes. All of these new operations will be accompanied by a rapid growth in population which will put further stress on the water resources as well as the existing sewage plants. The Waterberg region is part of the Bushveld which can be classified as a hot and an arid region. Due to irrigation that currently exist in the region, which stems from the climate conductive to agriculture production and its current mining development, based on the vast mineral deposits present, the current water availability and water use in the Waterberg region is relatively in balance. Meaning that the available water resources in the Limpopo basin will not be able to meet the domestic and industrial demands for water that the new developments will pose and the flows in several rivers have already changed from perennial to seasonal and episodic. In order to satisfy the demand of water that will be required by the above mentioned projects, the Mokolo Crocodile Water Augmentation Project will supply additional water to the region. However, this area still contains a relatively high number of natural or near-natural ecosystems, and it is important that this natural capital is not significantly eroded in the development process. This is possible with effective environmental planning to limit and mitigate negative social, ecological and economic impacts.

This project promotes science-based environmental assessment and planning by developing an understanding of key aquatic ecological indicators and their associated thresholds. The project vision is to promote improved outcomes for stream and river ecosystem health, and ultimately human health and well-being in the Waterberg area. The outcomes of the study will be used to detect existing processes of change in aquatic ecosystems and estimate the likely future changes that increased coal mining, human population and water transfers will cause.

Abstract

Different biological and chemical transport results are evaluated in this study. Ecoli and PDR1 were selected as the biological tracers with salt and rhodamine as chemical tracers. The transport experiments were evaluated through the primary aquifer material found at the University of the Western Cape research site. A series of controlled experiments under laboratory and field conditions was conducted. Each provides a different kind of data and information. The results from laboratory studies could be used to better design the field studies. In both cases, the data collected was to provide information on fate and transport of microbes in groundwater. The field design phase of the experiment was an up-scaling of the laboratory phase of this project. The amount injected into the aquifer was increased in proportion to the size of the research site. Tracer tests using chemical and microbial tracers were carried out simultaneously. Results of laboratory tests show a 5 times slower transport of microbes, compared to salts.. The salts at field scale show a breakthrough occurring after 2 days whereas the microbes never managed to breakthrough with the experiment stopped after 45 days. A new borehole was drilled closer to reduce distance/ travel time, but this had no effect on field results for the microbes. {List only- not presented}

Abstract

The groundwater governance arrangements for the development of groundwater resources were analysed. The analysis highlighted gaps and barriers to overcome before unconventional gas (shale gas and coal bed methane) development can take place at an industrial scale. The following governance challenges were identified (i) setting baseline measurements to detect groundwater pollution and to determine resource status; (ii) review of licenses and setting conditions for the development of unconventional resources; (iii) compliance monitoring and enforcement systems in place (iv) dealing punitively with non-compliant operators (v) mitigation options in place to prevent groundwater pollution; (vi) goal-based regulatory framework in place rather than a prescriptive regulatory framework; (vii) disclosure of hydraulic injection fluid; (viii) coordination with other government departments and regulatory bodies; (ix) a framework for subsidiarity and support to local water management; and (x) an incentive framework that support good groundwater management. To overcome the challenges requires a decentralized, polycentric, bottom-up approach, involving multiple institutions to deal with unconventional gas development. This provides better conditions both for cooperation to thrive and for ensuring the maintenance of such institutions.

Abstract

The Elandsfontein aquifer is currently under investigation to assist with the management of the system and to ensure the protection of the associated Langebaan lagoon RAMSAR site. The Elandfontein aquifer unit is situated adjacent to the Langebaan Road aquifer in the Lower Berg River Region and is bounded by the Langebaan Lagoon, possible boundary towards Langebaan Road aquifer, the Groen River bedrock high and the Darling batholith. The study will investigate the boundaries and hydraulic characteristics of the different aquifers and aquitards (Elandsfontein clay layer) in the Elandsfontein unit and their relationship to the Langebaan Lagoon. A literature review and baseline study has been completed to determine groundwater flow patterns and the general distribution of water quality, using historic data to characterize the different aquifers and aquitards of the system. An initial conceptual model has been formulated based on this data. Pumping tests will be used to acquire hydraulic characteristics of the Elandsfontein aquifer where data gaps exist, together with water quality and stable isotope sampling. Future plans are to construct a groundwater numerical flow model of the Elandsfontein system to assist with the management of the complex relationships between the recharge areas, flow paths through the different aquifer layers and aquitards towards the Langebaan Lagoon discharge. Results will be presented using graphical methods such as time series graphs amongst the monitoring boreholes over the years, piper diagrams to show water type characterization (Na-Cl type water) and initial results from the groundwater flow model. The expected results are envisaged to advance knowledge on groundwater availability and quality to inform the decision about water resource protection and utilization. Therefore this study is designed to provide large-scale background information that will improve the knowledge and understanding of the Elandsfontein aquifer unit and provide a basis for potential future studies of a more-detailed nature.

Abstract

In order to obtain a better understanding of a groundwater system, it is very important to understand the recharge mechanisms of such a system. Several intensive investigations have been done, documenting the different methodologies to derive recharge. Most of these studies have been centred on the detailed analysis and description of isotopes, which are either a characteristic of the water, the rock, or both. The isotopes of strontium, in particular the isotopic 87Sr/86Sr ratio, is one of such methodologies applied to drive the sources of recharge. The Oshivelo management area is part of the greater Owambo Basin, with no major rivers flowing through the project area, while the Omuramba Owambo, which crosses the area from east to west, bears water only rarely. This rural area therefore heavily relies on groundwater resources. Towards the end of the 20th century, through exploratory drillings an artesian aquifer in the southern part of the Owambo basin was discovered. Several investigation and water supply boreholes have been drilled, with the major findings summarised: - In the late 1990s DWA (DWA, 1999) drilled 12 exploration boreholes and six observation boreholes, showing high yields ranging between 40 and 200 m?/h. One of the boreholes yielded saline water, classified under the Oshivelo Artesian Aquifer and it was recognized that there may be a risk of saltwater intrusion when beginning to exploit the aquifer. It was assumed that the aquifer receives local recharge from the Etosha Limestone Member aquifer in the order of 3.75 MCM/a and additional unquantified recharge from the Otavi Dolomite Aquifer. - In the early 2000s KfW funded a study of the Tsumeb area, including the development of a groundwater flow model according to which an amount of 31 MCM/a would be leaving the Tsumeb area at the northern model boundary, i.e. flow into the Oshivelo Region. - The DWA plans to supply the north-western Oshikoto Region with water from the KOV2 aquifer via a pipeline in order to overcome water shortages there and to become more independent from surface water supplies from Angola. Though, through the groundwater model, a first estimate of groundwater resources availability has been established, the source of recharge is yet to be determined, including the flow mechanisms. Without, this vital piece of information, a valuable groundwater resource may be eventually utilized unsustainably. This presentation will focus primarily on the determination of groundwater recharge mechanisms, which would produce additional input to refine the existing groundwater flow model, concentrating on the Oshivelo Aquifer system. Upon the successful completion of this investigation, the next step would then be to evaluate the groundwater flow model and use it for a proper groundwater management plan. {List only- not presented}

Abstract

Noble gases are used in this study to investigate the recharge thermometry and apparent groundwater residence time of the aquifers on the eastern slope of the Wasatch Mountains in the Snyderville Basin of Summit County, Utah. Recharge to and residence time for the basin aquifer in the Salt Lake Valley, Utah, from the western slope of the Wasatch Mountain range by 'mountain-block recharge' (MBR), is a significant source of subsurface flow based on noble gas and tritium (3H) data. The Snyderville Basin recharge thermometry from 15 wells and 2 springs indicates recharge temperatures fall within the temperature "lapse space" defined by the recharge thermometry determined in the study of MBR for the Salt Lake Valley and the mean annual lapse rate for the area. Groundwater residence times for the Snyderville Basin were obtained using tritium and helium-3 (3He). The initial 3H concentrations calculated for the samples were evaluated relative to the 3H levels in the early 1950s (pre-bomb) to categorize the waters as: (1) dominantly pre-bomb; (2) dominantly modern; or (3) a mixture of pre-bomb and modern. Apparent ages range from almost 6 years to more than 50 years. Terrigenic helium-4 (4He) is also used as a groundwater dating tool with the relationship between terrigenic 4He in Snyderville Basin aquifers and age based on the apparent 3H/3He ages of samples containing water from only one distinct time period. The 4He is then used to calculate groundwater residence times for samples that are too old to be dated using the 3H/3He method. The mean groundwater residence times calculated with both methods indicate the water yielded by wells and springs in the Snyderville Basin generally ranges from 6 to more than 50 years. In addition, the calculated terrigenic 4He age for the pre-bomb component of many samples was found to exceed 100 years. While terrigenic 4He residence times are not as definitive as those calculated with the 3H/3He method, or chlorofluorocarbons (CFCs), age dating with terrigenic 4He allows initial estimates to be made for groundwater residence times in the Snyderville Basin, and is an important tool for establishing groundwater residence times greater than 50 years. Historic water levels from production wells indicate a declining water table. This trend in conjunction with precipitation data for the area illustrates the decline in the water levels to be a function of pumping from the aquifers. Groundwater residence times in the Snyderville Basin and declining water levels support the need for a groundwater management program in the Snyderville Basin to effectively sustain the use of groundwater resources based on groundwater age. {List only- not presented}

Abstract

Underground Coal Gasification (UCG) is an emerging, in-situ mining technology that has the advantage to access a low cost energy source that is currently classified as not technically or economically accessible by means of conventional mining methods. As such it offers significant potential to dramatically increase the world's non-recoverable coal resource.

Groundwater monitoring in the South African mining industry for conventional coal mining as an example, is well established, with specific SANS, ASTM and ISO Standards dedicated for the specific environment, location and purposes. In South Africa a major impact of the coal mining industry can be a reduction in the groundwater quantity and quality. South-Africa's groundwater is a critical resource that provides environmental benefits and contributes to the well-being of the citizens and the economic growth. Groundwater supplies the drinking water needs of a large portion of the population; in some rural areas it represents the only source of water for domestic use. Utilization and implementation of groundwater monitoring programs are thus non-negotiable.

The groundwater quality management mission, according to the Department of Water and Sanitation in South-Africa, is set in the context of the water resources mission and is as follows:

"To manage groundwater quality in an integrated
and sustainable manner within the context of the National
Water Resource Strategy and thereby to provide an
adequate level of protection to groundwater resources
and secure the supply of water of acceptable quality."

The scope of this paper is to propose an implemention strategy and a fit-for-purpose groundwater monitoring program for any Underground Coal Gasification commercial operation. It is thus important to pro-actively prevent or minimise potential impacts on groundwater through long-term protection and monitoring plans. A successful monitoring program is one that consists of
(1) an adequate number of wells, located at planned and strategic points;
(2) sufficient groundwater sampling schedules; and
(3) a dedicated monitoring program and quality control standard.

In order to have an efficient monitoring program and to prevent unnecessary analysis and costs, it is also critical to determine upfront what parameters have to be monitored for the specific process and site conditions.

Abstract

{List only- not presented}

Abstract

Since the first decant of acid mine drainage in the West Rand in 2002, a great deal of effort has gone into researching the challenges which it poses there and in the adjacent Central Rand and East Rand Gold Fields. Short-term interventions have been implemented to maintain water at conservatively-determined safe levels and remove the worst contaminants from the water pumped from the mined. A feasibility study, looking at the long-term options has proposed treatment of water to a much higher standard, identifying a number of potential end-users of the treated water and highlighted the extremely high costs involved in responsible management. During the second half of 2010, a team of experts was convened to assess problems related to acid mine drainage in the Witwatersrand and propose solutions. A number of recommendations were made and the most urgent - the need for a short-term intervention to bring things under control and the the feasibility study for long-term management of the problems were undertaken. Nevertheless, despite the intense focus on the problem, a number of questions have remained unanswered. Throughout the period of min flooding, no detailed systematic monitoring of surface water flow has been undertaken, preventing the detailed apportionment of pollution between underground and surface sources. Ingress control measures have been proposed, but funding mechanisms, regulatory hurdles and challenges relating to long-term management have not all been comprehensively addressed. On a more positive note, the installation and operation of pumps to control the water level in the Western and Central Basins will start to provide valuable data regarding the response of the flooded mine workings to pumping, assisting in the characterisation of the hydraulic properties and behaviour of the large voids. This will facilitate the optimisation of pumping strategies and the refinement of environmental critical levels and assist in the development of more sustainable management options.

Abstract

POSTER The Department of Water and Sanitation (DWS) is the custodian of South Africa's water and thus is imperative that it reports on its state as the National Water Act of 1998 requires regular reporting to Parliament by the Minister. Hence, the annual compilation of report entitled "The National State of Water in South Africa." This report aims to give an overview of the status and trends of water quality and quantity, further assisting with international water reporting obligations to SADC Region, African Continent, and Globally e.g. the United Nations Commission on Sustainable Development. This information empowers the public and provides knowledge to water managers for informed decision-making. The main purpose is to enhance quality, accessibility and relevance of data and information relating to the goal of Integrated Water Resource Management towards attaining holistic Integrated Water Management, and Integrated Water Cycle Management in future. Three distinct requirements for collecting data by DWS are: (i) assessing and comparing the status and trends for both quantity and quality; (ii) monitoring for water use and (iii) monitoring for compliance to licence conditions. Such information is further used to assess the effectiveness of policies implemented and identify the existing gaps. Various challenges to the country's water demand proper integrated water resources planning and management. The report is divided into Themes such as, Resource Management, Water Services/Delivery, Water Development and Finance, based on selected indicators. The indicators are strategically selected to provide a representative picture of the state, as well as the changes over time to the drivers, pressures, impacts and responses related to the chosen themes. These Indicators include: Climatic Conditions, Water Availability, Water Use, Water Protection, Water Quality, Water Service Delivery, Water Infrastructure, Water Finance, and Sanitation. The report for Hydrological Year 2013/2014 has been completed and it shows that the amount of water available varies greatly between different places and seasons, and from one year to another. The average total storage was around 85% of full supply capacity in September 2014. Surface water quality is generally facing a threat from eutrophication and microbial pollution emanating mainly from mismanaged water (and waste) treatment plants and related landuse activities. Groundwater quality is generally good except in some localised areas where mining and industrial activities are prevalent. With regards to infrastructure; vandalism, lack of maintenance & management skills reflect on/as non-revenue water, highlighting the need for more funding towards maintenance, especially in groundwater which is normally wrongly deemed as an unreliable resource. In the past 20 years, water services delivery to communities has improved as the Millennium Development Goals have been met and surpassed, while the sanitation access goals were likely to be met.

Abstract

Identifying and characterising the vertical and horizontal extent of chlorinated volatile organic compound (CVOC) plumes can be a complex undertaking and subject to a high degree of uncertainty as dense non-aqueous phase liquid (DNAPL) movement in the subsurface is governed most notably by geologic heterogeneities. These heterogeneities influence hydraulic conductivity allowing for preferential flow in areas of higher conductivity and potential pooling or accumulation in areas of lower conductivity. This coupled with the density-induced sinking behaviour of DNAPL itself and the effects of groundwater recharge in the aquifer result in significant challenges in assessing the distribution and extent of CVOC plumes in the subsurface. It has been recognized that high resolution site characterization (HRSC) can provide the necessary level of information to allow for appropriate solutions to be implemented to mitigate the effects of subsurface contamination. Although the initial cost of HRSC is higher, the long-term costs can be substantially reduced and the remedial benefits far greater by obtaining a better understanding of the plume characteristics upfront. The authors will discuss a case study site in South Africa, where ERM has conducted HRSC of a CVOC plume to characterise the distribution of the source area and plume architecture in order to assess the potential risk to receptors on and off-site. The source of impact resulted from the use of a tetrachloroethene (PCE)-based solvent in an on-site workshop. The following methods of characterization were employed:
- Conducting a passive soil gas survey to identify and characterise potential source zones and groundwater impacts;
- Vertical characterisation of the hydrostratigraphy, contaminant distribution and speciation in real time using a Waterloo Advanced Profiling System (APS) with a mobile on-site laboratory;
- Using the Waterloo APS data to design and install groundwater monitoring wells to delineate the vertical and lateral extent of contamination; and
- Conducting a vapour intrusion investigation including sub-slab soil gas, indoor and outdoor air sampling to estimate current risk to on-site employees.
In less than a year, the risk at the site is now largely understood and the strategies for mitigating the effects of the contamination can be targeted and optimised based on the information gained during the HRSC assessment.

Abstract

The mineral rich Northern Cape Province produces 84% of South Africa's iron ore, while the Kalahari basin holds 92% of the world's high grade manganese deposits, with diamond and lime mining operations to a lesser degree. Mining expansion programs and new mines planned in the Northern Cape drive the region's economic development and growth strategy. The planned mining expansion depend on water being available for mining water needs and related increased demands for domestic water supplies.

Current water supplies consist of local groundwater resources (boreholes and mine dewatering) and bulk water supply from the Vaal Gamagara (VGG) Pipeline Scheme. In 1992 the Kalahari East water supply pipeline was incorporated to supply domestic and stock water to an area of approximately 1.4 million ha.

The VGG scheme consists of 370 km pipes, was built in the late sixties and is nearing its useful life expectancy. Increased water supply interruptions are being experienced while operating at capacity. The pipeline has the capacity to convey and import water of approximately 15 million m3/a into the D41J and D41K quaternary catchments. Water demand projections show an increase to 40.1 million m3/a in 2030.

Various options were investigated to upgrade the VGG water supply scheme. One option considers groundwater resources to augment the water from the Vaal River from four indentified target areas (SD1 to SD4).

Major fault zones in Banded Iron Formations (BIF) are targeted for groundwater resource development in the SD4 area, located east of Hotazel. This area is largely covered by Quaternary age sand and located near the endpoint of the VGG scheme and therefore prioritized as investigation area.

The primary objective of the hydrogeological investigation was to identify the existence of exploitable resources for additional source development. Secondary objectives were to assess the contribution groundwater can make to augmenting pipeline water; providing a source to an area and thus diminish reliance on the pipeline; and providing an independent source, which could prevent the need for pipeline extensions.

The paper will discuss the use of an airborne magnetic and Time Domain Electromagnetic's (TDEM) survey combined with gravity ground surveys as a key success factor in adding to the geological and structural information of the area. The paper will also present the results of exploration drilling (> 60 boreholes) over a large area and related borehole test pumping with water sampling to identify a sustainable and potable water supply of 2.5 million m3/a.

Abstract

POSTER Water resources are not just lakes, glaciers and polar ice caps and rivers; however one of the largest water resources is underground water well-known as Groundwater. Groundwater is one of the most important source of water as it the huge reservoir for freshwater. Groundwater can be defined as water existing underneath the earth surface in rock bodies known as aquifers. Approximately 140 communities in South Africa depend on groundwater as the source of water (Department of water affairs and forestry, 1998). Nevertheless groundwater is vulnerably to pollutants resulting from surrounding environmental effects which lead to poor groundwater quality. Numerous environmental effects have a huge impact in polluting groundwater such as pesticides, seawater encroachment, sewage effluent discharges to the ground and storage tanks underground; hence one need to identify, evaluate and come up with solutions on eradication of all these environmental effects that lead to groundwater pollution ( Hearth 1983).

The objectives of the report will be based on minimizing the groundwater pollution at the source and to restore groundwater quality to extent that the beneficial users recognise its suitability. Inspection in University of the Western Cape (UWC) campus site and Rawsonville site will be conducted by BSc Environment and Water Science students of UWC in June using various tools in order to identify and monitor surrounding environmental effects towards groundwater pollution. UWC campus research site is located on top of the Cape Flats primary aquifer (unconfined sand aquifer); Cape Flat aquifer is overlain by an impermeable bedrock Malmesbury (shale) secondary fractured aquifer. Generally this borehole test will be based on testing on how the surrounding environmental impacts with various aquifer properties affect the groundwater quality or whether the surrounding environment interrupts the groundwater quality in Cape flats aquifer and Rawsonville site. The UWC campus site has low infiltration compared with Rawsonville site as it is surrounded by vegetation that plays role in trapping water from infiltrating therefore this aquifer is less likely to be contaminated by pollutants from the land surface, however with it being surrounded by residential areas and industries it is likely to be polluted. Rawsonville on the other hand is located in the grape farm which makes it easier for the site to be contaminated by fertilisers used for agricultural practice. The pumping test will further enable one in knowing the quantity of groundwater in UWC campus site and Rawsonville site thus extraction levels for municipal works, irrigation and so forth will be monitored in a correct manner (Department of water affairs and forestry, 1998). Finally groundwater models will be used to further investigation on the behaviour of groundwater systems.

Abstract

Artesian boreholes are a common feature worldwide in confined aquifers, but the hydraulic testing of these boreholes, and estimation of aquifer properties from such tests, still poses a challenge for hydrogeologists. Common hydraulic tests, such as step-drawdown or constant-discharge rate tests require a static water level at the start of the test, and the measurement of drawdown (increasing over time) and abstraction rate (fixed for a period of time). Usually, when undertaking a pumping test in an artesian borehole, the drawdown is measured from ground level, and the drop in hydraulic head between static pressure and ground level is often ignored. This procedure also implies that the starting time of the test is not at the static water level. A constant-head test, set at ground level, is the other option. However, the decrease in flow rate is not only dependent on the hydraulic properties of the aquifer, but also masked by pipe hydraulic effects within the well. This kind of test would also limit the available drawdown to be utilized for the test. Hence, it was required to develop a method for undertaking hydraulic tests in strong artesian boreholes, allowing for the drawdown to fluctuate between levels both above and below ground and avoiding the pitfalls described above. The solution is a specially designed and constructed wellhead for the installation of the pump and monitoring equipment prior to the hydraulic test. The standard tests are slightly modified and are only undertaken after sealing the wellhead and reaching static hydraulic pressure. The recommended wellhead construction and subsequent hydraulic tests were implemented at a strong artesian borehole in the Blossoms Wellfield, south of Oudtshoorn in the Western Cape province of South Africa.

 

Abstract

The National Water Act (NWA) 36 of 1998 is regarded as providing a platform for an innovative way of managing the country's water resources. However, demands on the nation's water resources are intensifying as more and more catchments are coming under increasing stress. This may be attributed to significant changes in land-use and poor water resource governance which negatively affects the Environmental Water Requirement (EWR) flows of rivers in many catchments in South Africa. EWR refers to the flow needed by a river to sustain a healthy ecosystem. It is vital that the determined EWR flows are met and to ensure that all water-users receive their allocated water supplies. To ensure effective water management and water provision, it is critical to understand transmission losses considering that it is a key component of the water balance or hydrological budget. Quantitative investigations of transmission losses are necessary in order to calculate flows in a river and appropriately allocate water for different users. The Groot Letaba River situated in the north-eastern region of South Africa is a prime example of a river system where uncertainties in channel losses and gains are complicating effective water management. The Groot Letaba River is a model river where Strategic Adaptive Management (SAM) is currently being implemented to ensure adaptive and sustainable water resource management. This unique approach is facilitated by the institutional interaction between dam operators (from the upstream Tzaneen Dam) and stakeholders including Kruger National Park. However, there are huge uncertainties surrounding natural water losses (e.g. evapotranspiration) or gains (e.g. groundwater discharge) in the real-time model currently being used by dam operators. This study aims at attempting to narrow down the uncertainty by understanding and quantifying the natural hydrological processes between the two dominant land-uses along this river, i.e. agriculture and protected areas. In particular, the project will investigate the hydrological connectivity between groundwater and surface water along the Letaba River. This project will contribute significantly to management strategies by using a precise hydrological approach which will aid in improving estimates of water supply in the Groot Letaba River. Furthermore, this project could contribute to the development of appropriate water management strategies not only in the Letaba catchment but other similar Lowveld catchments as well.

Abstract

Faced with a burgeoning population and property growth, and in preparation for a future drier climate regime; the coastal town of Hermanus in the Western Cape has set up two wellfields to abstract groundwater from the underlying aquifer in order to augment the constrained surface water supply from the De Bos Dam.
Water Use Licences (WUL) were issued to the Overstrand Municipality in June 2011 and December 2013. The licences authorise a maximum annual abstraction of 1 600 Ml of water from the Gateway wellfield and 800 Ml of water from the Volmoed and Camphill wellfield via several boreholes. The water abstracted from the Gateway wellfield is pumped via a booster pump station to the Preekstoel Treatment Plant. The Volmoed and Camphill wellfield are situated at a higher altitude allowing for a gravity feed pipeline.
Earth Science Company, Umvoto Africa, has the responsibility to ensure Resource Quality Objectives are met which include balancing the need to protect the resource on the one hand; and the to develop sustainable utilisation of the Hermanus groundwater resources and compliance with the WUL on the other. The consultancy provides hydrogeological support, wellfield management and technical advice in operating the boreholes, pumps, boosters and related infrastructures.
Running the operations of the wellfield relies on a high-tech, semi-automated system, incorporating a remotely controlled, telemetry based structure. Vital parameters are monitored by electronic sensors, feeding data to processors which alters pump performance to maintain specified boundary levels. Data is simultaneously communicated via telemetry to a central control which uses data acquisition software to portray information to the operators. Warning alarms both alert operators via SMS and in certain instances auto-shut down the system.
To ensure ecological sustainability of the ground water resource, the wellfield also requires hydrogeological monitoring at far field locations within the recharge areas. Some of these locations are in remote areas making data download costly. The high-tech telemetry approach is used with positive results.
Any automated telemetry system is prone to malfunction and environmental hazards. The challenge lies in managing this and providing sufficient back up and duplication of systems.
The paper gives an overview of the components and flow of data based on the experiences gained during the evolution and development over 12 years of operation. Automation produces vast data bases which are often not sufficiently analysed, the premise that "once collected, the task is done". However data is only as good as the people who drive the systems and this paper provides a critical analysis of human intervention in an automated system and the decisive role of quality-checks. Finally the paper seeks to provide a pragmatic guideline for water users to comply with the WUL and institutional regulations.

Abstract

A groundwater assessment was conducted to identify and predict the contamination and transport properties of a groundwater system. The motivation for the study was the rising concern of a farm owner about the deteriorating water quality of the aquifer system. An investigation of the surface and groundwater quality indicated that two fertilizer dumpsites were the sources of pollution. Water analyses revealed elevated concentrations of Ca, Mg, K, F, NO3, SO4, Mn and NH4 within boreholes near the pollution sources. The NH4 and NO3 concentrations were exceptionally high: 11 941 mg/L and 12 689 mg/L, respectively. These high concentrations were the direct result of the dumping of fertilizer. The rise in these concentrations may also have been catalysed by the nitrogen cycle and the presence of the Nitrosomonas bacterium species. Due to the high solubility of NO3, and because soils are largely unable to retain anions, NO3 may enter groundwater with ease, and could migrate over large distances from the source. Elevated NO3 in groundwater is a concern for drinking water because it can interfere with blood-oxygen levels in infants and cause methemoglobinemia (blue-baby syndrome). A geophysical study was undertaken within the area of investigation to gain insight on the underlying geological structures. The survey indicated preferential flow paths within the aquifer system along which rapid transport of contaminant is likely to occur.
Key words: aquifer system, groundwater quality analyses, fertilizer, nitrogen cycle, Nitrosomonas species, geophysics.

Abstract

VLF-Electromagnetic and geoelectric soundings were carried out at Ibuso-Gboro area via Ibadan, Oyo state. The objective was to delineate the groundwater potentials of the area. VLF-Electromagnetic method was adopted for reconnaissance survey with a view to locating bearing fractured zones in the basement bedrock. Sixteen (16) VLF-Electromagnetic profiles whose length ranges from 90-290 m were occupied with station interval of 10 m. The VLF-Electromagnetic results were presented as profiles. Linear features, suspected to be fractured zones, which were from the anomaly curves of the VLF-Electromagnetic were delineated in seven localities along the profiles. These localities were further confirmed by Vertical Electrical Soundings (VES). The seven Schlumberger Vertical Electrical Soundings (VES) were occupied with the electrode spacing (AB/2) varying from 1 m to 100 m with the total spread length of 200 m. The VES data were presented as sounding curves and interpreted by partial curve matching and computer assisted 1-D forward modeling. The results were presented as geoelectric sections, which showed the subsurface geoelectric images. Two out of the seven delineated linear features were test drilled and the fractured zones were met at depth range of between 25.0 m and 38.2 m beneath borehole (1) and 43.0 m and 52.1 m beneath borehole (2) for confined fractured. The pumping test analysis revealed borehole yield varied from 4.8 m3/hr and 5.2 m3/hr, where three (3) abortive boreholes had earlier been drilled. {List only- not presented} Key Words: VLF-Electromagnetic, Linear features, Geoelectric Soundings and Pumping test.

Abstract

POSTER The human interferences in river catchments includes impoundment construction, sediment mining, bank revetment and artificial cutoff, which eventually leads to changes in the hydrology system and channel transportation ability, and may reduce channel stability. In past 10 years the Kuils River had been upgraded between Van Riebeeck Road and the Stellenbosch Arterial route to reduce flood levels. The stretch of the river between the R300 and Van Riebeeck Road was also upgraded: reducing any possibility of flooding, by concrete-lining of some areas of the river that are within the Kuilsrivier Municipal Area. Producing a cross-section of a river channel is of great importance in river studies. To determine the discharge one should survey the profile of a feature such as a meander or riffle, it is necessary to produce a cross-section of the river. In order to focus on restoration requirements of a river, a map of the river is needed. This provides an indication of what exactly the river currently is. Habitat mapping is intended to access the stream. Woody debris, substrate, aquatic vegetation is measured continuously throughout a river, to be able to identify conservation and restoration needs. The cross section 1.3 of site 1 indicates that the channel width from January 2002 is almost similar in width of September 2012. The depth of the channel is about 0.5m deeper when compared to January 2002. The Kuils River banks are covered in grassy vegetation, with some trees with deep and large roots that provide protection against undercutting along rivers. The banks of Site 1 are covered long weeds and annual grasses with shallow root systems, which don't provide stability when the banks were saturated after high rainfall. The Kuils River area is used for various types of land uses and this also impacts the channels eg. Urban, Industrial and Agricultural use. Because of canalization occurring upstream one can see evidently the changes within the channel.

Abstract

Vacuum Enhanced Recovery (VER) has widely been applied in many hydrocarbon contaminated site to recover liquid hydrocarbon from the subsurface Hydrocarbon contamination to groundwater and soil is usually as results of leak or release. Different technologies and method exist to treat contaminated groundwater and soil through hydrocarbon. This paper focuses on the efficiency of VER as alternative method to the site where over 6 000 litres of petrol leaked to the subsurface over a period of time. The application of VER involves creating a capture zone in a particular monitoring well by increasing the hydraulic gradient towards that particular well or set of wells affected by hydrocarbon.

Abstract

The way in which groundwater is utilized and managed in South Africa is currently being reconsidered, and injection wells offer numerous possibilities for the storage, disposal and abstraction of the groundwater resource for municipalities, rural communities, mining, oil and gas, and a multitude of other industries. This presentation is about the North Lee County Reverse Osmosis Water Treatment Plant Injection Deep Injection Well project in southwest Florida in the United States. Water is plentiful in Florida, but it is not drinking water quality when it comes out of the ground. As such, treating water from wells is an important part of water supply in the coastal regions of the state. One form of treatment is reverse osmosis (RO), which generates a brine concentrate waste. The concentrate must then be disposed of, and a preferred method of disposal is an injection well because the disposal is not visible to the general public. The injection well project was associated with the construction of a large water treatment plant. The emphasis of this presentation is on the drilling and technical work in the field for this injection well, and to illustrate the rigorous requirements of drilling, constructing and testing a Class I injection well. Class I injection wells are permitted by the United States Environmental Protection Agency (US EPA) for injecting hazardous waste, industrial non-hazardous liquid, and/or municipal wastewater beneath the lowermost Underground Source of Drinking Water (USDW). Aquifer storage and recovery (ASR) wells are permitted as Class V injection wells by the US EPA. The permitting of an injection well is rigorous and requires state and federal approval before, during and after the field portion of the project. {List only- not presented}

Abstract

Resources required for groundwater sampling includes but not limited to pumping equipment, trained manpower and technical resources specific to the sampling function. Bearing these expenses in mind, choosing a laboratory for testing the water samples collected should be a carefully considered purchase. Choosing a testing facility that cannot deliver an efficient, reliable and technically sound service could render the sampling futile.

Water samples submitted to a laboratory for testing are received from third party sources more than ninety percent (90%) of the time and sampling techniques and sample integrity cannot be verified by the laboratory. However, the validity, reliability and integrity of the laboratory testing are within the control of the testing facility. These aspects of a laboratory are usually controlled within a quality management system where established policies and procedures form the basis of such a system. This system maintains a foundation for technical competence and customer service at the laboratory.

There are numerous testing facilities available to Consultants requiring chemical and microbiological groundwater testing, each with varying levels of integrity and technical ability. It is imperative to maintain confidence in the validity of results of analyses from a laboratory and this assurance can be understood through an examination of a facility's management system.

An established quality management system would comprise a policy statement, associated technical methods and technical and administrative procedures. This system would be formally documented and audited as part of the on-going laboratory's management system. In some instances, laboratories formalise this into an accreditation of the laboratory to an international standard, such as ISO 17025:2005.

The assurance that the results of analyses from any laboratory are of sound technical integrity would depend on factors such as
- personnel training,
- accommodation and environmental conditions under which the tests are carried out,
- validation of the methodology applied (including the uncertainty of measurement),
- the calibration and maintenance of the equipment used,
- understanding the traceability of and measurement undertaken,
- handling and preservation of the sample on receipt and while in the laboratory.

Each of these factors plays a critical role in the integrity of results of analyses and should be interrogated when trying to understand the reliability and competence of the laboratory of choice.{List only- not presented}

Abstract

Understanding the hydrogeology of fractured or crystalline rocks could be complicated because of its complex structure and a porosity that is almost exclusively secondary. These types of geologies are known to exhibit strong heterogeneities and irregularities contrasted in hydraulic properties, spacing and flow distribution within fractured rock aquifers. Therefore it is important to develop a conceptual model based on site specific data such as the hydraulic roles between groundwater and nearby hillslope/surface water bodies in order to understand its movement within the environment. Therefore this study intends to develop a hydrogeological conceptual model to qualitatively interpret the dominant groundwater flow processes at a 3rd order scale within southern granite supersite of the Kruger National Park (KNP). Key findings based on actual subsurface results in the form of Electrical Resistivity Tomography (ERT) surveys, borehole drilling logs, water levels and hydraulic data suggest that two aquifer types exist on the southern granite supersite namely, a weathered low resistivity of 3-75 ?m (average depth ranging 383-328 mamsl) and hard rock high resistivity of 1875-5484 ?m (average depth ranging 364-299 mamsl) granite/gneiss aquifer. The weathered aquifer flow system responds to localized processes such as piston recharge, indirect surface water recharge and groundwater water discharge via interflow. This was due to the relatively rapid response time of 2-3 weeks in groundwater levels to the major sequence of rainfall events over the hydrological year. The hard rock aquifer is part of a regional groundwater flow system. This is owed to the lengthy response time lags of 2-3 months in groundwater levels to the major sequences of rainfall events over the hydrological year. Due to the generally low transmissivity (ranging 9.50E-08 to 11.2 m2/day) values obtained during the borehole pump and slug tests and inclining trend of groundwater levels after the wet season, suggest these ephemeral hillslope landscapes are likely to act as hydraulic boundary areas. In that they contribute during the dry season to the regional hydraulic head generating baseflow to perennial streams. Therefore from a management perspective certain reaches within these ephemeral streams contribute to recharge which in turn should receive attention as many of the ephemeral stream sand are used for grading tourist gravel roads. Furthermore these granite ephemeral landscapes are characteristic of generally low transmissive aquifer properties and therefore should be given careful consideration before including it in a water supply scheme scenario.

Abstract

The Saldanha / Langebaan area is expanding at a significant rate, increasing the water demand for the area. The expansion comes from the industrial, residential and tourism sector. In addition there are economically viable deposits of silica and phosphate in the area. Ecosystem functioning in the area is also to a degree dependent on groundwater. All of these factors require an improved understanding of the geohydrology of the area. The geology of the area consists of basement Cape Granite and Malmesbury Group rocks that underlie the sediments of the Sandveld Group. The unconsolidated formations present, are (in order of oldest to youngest) as follows: - Elandsfontyn Formation (oldest): This formation overlies the bedrock in depressions and palaeo-channels in the bedrock. This formation is about 40 m thick and is composed of upward fining quartz sediments. - Varswater Formation: This formation is composed of marine deposits and is restricted to the western (seaward) parts of a bedrock depression to the east of the Langebaan Lagoon and Saldanha. The formation is characterized by rounded quartz grains. - Langebaan Formation: This formation consists of calc-arenites. The sediments are generally grey to cream coloured and consist of quartz and shell fragments, the grain size ranges from coarse to fine and the consolidation is variable. - Witzand Formation (youngest). This formation consists of light-coloured, calcareous, coastal dune sand that can be distinguished from the underlying consolidated Langebaan Formation. The Elandsfontyn Aquifer System (EAS) and the Langebaan Road Aquifer System (LRAS) are the main aquifer systems in the area. These aquifer systems are defined by palaeo-channels that have been filled with gravels of the Elandsfontyn Formation and represent preferred groundwater flow paths. Within each of these aquifer systems (EAS and LRAS) two aquifer units are present. Namely, the confined Lower Aquifer Unit (LAU) geologically consisting of the basal gravels of the Elandsfontyn Formation and the Upper Aquifer Unit (UAU) composed of consolidated sands and calcrete. The two units are separated by a clay aquitard. A numerical model has been established for the area, and extends from the Berg River to the Langebaan Lagoon. Granite outcrop and river system define the other boundaries of the model. Extensive logging of groundwater levels by the Department of Water and Sanitation (DWS) has enabled the accurate establishment of a model. In addition extensive field work and a detailed hydrocensus, as well as the capture of a lot of historical information has resulted in a comprehensive GIS which assists with the refinement of the numerical model. The model provides a valuable tool in modelling potential impacts whether they been from planned groundwater abstraction or artificial recharge. {List only- not presented}

Abstract

POSTER Pine plantations require large amount of water for transpirational demand and the amount of water depend on the area of plantation and the rooting depth of plants.
The large amount of water required may result in disturbance of the natural water table equilibrium to meet the demand and insure growth.
The lake Sibayi catchment area is covered by the 65 km2 freshwater lake sibaya, 70km2 of pine and eucalypts woody plantations and crops.
The lake is recharged dominantly from groundwater and it is a water resource for local communities.
A large extraction of groundwater by plantations will decrease the water table and the lake level and that will decrease the amount of water available for local residences.
The main aquifer is composed of tertiary to quaternary age sediments which form a thin covering which blankets most of the Maputaland coastal plain and rests on a cretaceous system.
Shallow marine and beach deposits of tertiary origin overly the cretaceous aged silt, while the quaternary age sediments which constitute most of the cover are predominantly of Aeolian origin.
The Uloa formation of tertiary age is identified to be the most promising aquifer in the region consisting of coarse grained shelly sandstone with calcarenite associated with it.
The aquifer is approximately 40m in depth and it is recharged dominantly from rainfall through infiltration.
Rainfall averages 900mm per annum over the catchment but varies between 1200mm per annum in the south east and 700mm per annum in the west and evaporation equals to ? 1420 mm per annum (Pitman and Hutchinson, 1975).
Lake Sibayi is a freshwater lake of 65km2, in surface area and it is a water resource for surrounding communities and other inhabitants.
The sandy substrate surrounding Lake Sibayi limit the amount of surface runoff and consequently the water level within the lake are maintained by groundwater recharge.
The growth of plantations is influenced by the ability of trees to extract soil water from the intermediate zone below the root zone and the capillary fringe.
The water supply depends on the depth of the water table and on the structure of deposited soil layers and the water table depth is determined by the rate at which vegetation extracts water for transpiration and the recharge rate of groundwater.
The specific yield of a soil determines the amount of water that percolates to recharge groundwater and because vegetation extracts water from layers of soils above the water table they decrease the amount of recharge for groundwater.

Abstract

The national water balance is primarily based on the availability of surface water and the historic allocation thereof. The changes that are required the next 20 years to ensure sustainable development of the nation will be painful, but is unfortunately at present not part of the public discussion, it is essentially ignored in favour of more "popular water topics".This paper intends to look at a few core aspects, they include the current water allocation in the national water balance, the relative value of the utilisation, the position of groundwater resources in changing the current relative allocation and the current groundwater utilisation. The paper further intends to be a less formal presentation of these aspects with the required data, references and conclusions available for distribution afterwards.

Abstract

South Africa's water legislation of has often been deemed 'progressive', yet implementation of policies can be weak in terms of groundwater - a resource inherently more difficult to govern than surface water due to its invisibility, difficulties in mapping, the long timescales involved and its ties to land tenure. Furthermore, shallow, hard rock aquifers are frequently perceived as "self-controlling" by their users and thus not requiring active management. This view is however not optimal in areas with a large dependence on groundwater for livelihoods invoking the question what happens between the periods of over-abstraction and the recharge events that replenish them? There is a need for better management, particularly in light of climate variability when recharge episodes can be infrequent and drought can lead to extra calls on aquifers.

Seasonal climate forecasts have the potential to provide information to contribute to groundwater management strategies. This study focuses on the case of Dendron in Limpopo Province. Numerous consultancy reports have been released over the past few decades regarding the over-exploitation of groundwater due to the area's long history of potato cultivation via groundwater-irrigation. The primary aim of this study is to determine the potential contribution of seasonal forecast information in the Dendron area for agricultural groundwater management, given insights to the needs of commercial farmers in the area the dominant users of groundwater. We examine the effectiveness of formal and informal groundwater management strategies in the area and then consider current use of seasonal forecasts and their potential value for decision-making. We also highlight the need for a better understanding of the role of seasonal climate variability in groundwater systems to understand their potential as climate buffers during periods of drought. Insights will be drawn from interviews with farmers and representatives from the Department of Water and Sanitation, and a needs-analysis workshop with the farming community. Constraints and barriers to uptake are also investigated, looking at factors such as data quality and availability, timing of forecasts, perceptions of forecasts, and their communication.

Abstract

The anticipated exploration and exploitation of Shale Gas in the Eastern Cape Karoo through hydraulic fracturing has raised considerable debate regarding the benefits and risks associated with this process for both the Karoo, and the country as a whole. Major concerns include the potential impact of hydraulic fracturing on ecological, environmental and especially scarce water resources. The Eastern Cape Karoo region is a water stressed area and with further climate change it will become increasingly so. Thus, effective and reliable groundwater management is crucial for sustainable development in this region. This research aims to hydrochemically characterise both the shallow groundwater (<500m) and deeper saline groundwater in the vicinity of the Shale Gas bearing formations, based on major and trace elements, as well as gas isotope analyses. Sampling will include water sampling and gas measurements from shallow boreholes (<300m), SOEKOR drillholes (oil exploration holes drilled in the 60's and 70's up to 4km deep) and thermal springs (source of water >500m).

To-date, a desktop study includes the collation of information determining the areas with the highest potential for Shale Gas Exploration throughout the Eastern Cape Karoo, from which the research area has been determined. This includes the identification of the respective oil companies' exploration precincts. A Hydrocensus has been initiated across this area, which includes slug testing and electrical conductivity profiling of open, unequipped boreholes. Further borehole selection will be finalised from this acquired information. The boreholes will be sampled and analysed a minimum of three times per year, which will occur after summer (April/May) and winter (October/November), after which the hydrochemistry will be analysed. The sampling will be preceded by purging of all inactive boreholes. The possible hydraulic connectivity between the shallow and deep aquifers will be tested, particularly in those areas where dolerite intrusions as well as fault systems may enhance preferential flow of water, using the chemical forensics complemented with passive seismic profiling/imaging and deep penetrating Magneto-Telluric (MT) imaging.

The data collected will form a record against which the impact of fracking can be accurately determined. The research is a critical first step towards the successful governance of groundwater in light of the proposed Shale Gas development. In its absence, effective regulation of the sector will not be possible.

Abstract

Model calibration and scenario evaluations of 2D and 3D groundwater simulations are often computationally expensive due to dense meshes and the high number of iterations required before finding acceptable results. Furthermore, due to the diversity of modelling scenarios, a standardised presentation of modelling results to a general audience is complicated by different levels of technical expertise.

Reducing computational time
In this presentation we look briefly at the use of Reduced Order Models (ROM's), which is one of the recent developments in groundwater modelling. The method allows significant speed-up times in model calibration and scenario evaluation studies. In saturated flow for example, these approaches show speed-up times of >1000 when compared to full models created with Finite Element of Finite Difference methods. These methods are demonstrated to a case study in the Table Mountain Group, in which we show a simplified parameter calibration and scenario evaluation study.

Standardising presentation
In order to present the results to as wide an audience as possible, the use of a web-browser as a GUI is proposed, where the web-page is coupled to a geo-spatial database and data is presented in a spatial and numeric format. The use of the spatial database manager PostgreSQL with PostGIS is proposed. Through a browser interface, users can run modelling scenarios using the ROM, which is evaluated in near real-time. Following the evaluation of the model, we show how PostGIS can spatially present data on a base-map such as google maps. In keeping with the current trends in online map customisation, viewers can interactively choose to overlay the base-map with a data-type (such as pressure or hydraulic head contours or flow direction) that is most intuitive for their level of familiarity with the data.

Conclusion
In using advanced modelling techniques and a simplified browser based presentation of results, high-level decisions in water resource management can be significantly accelerated with the use of interactive scenario evaluations. Furthermore, by reaching a broader audience, public participation will be significantly enhanced.

Abstract

Cape Town... Home to over 3 and a half million people, the second most populated city in South Africa was born in the shadow of the Table Mountain. The mountain offered all the elements vital for human settlement... most importantly WATER. The reports of the abundance of fresh water and fertile land at the foot of the mountain and surrounds inspired the VOC to set up a refreshment station at the Cape. By the late-1800s, spring water was solely used for domestic supply to the settlers of Cape Town. Until the 1930s, the Stadsfontein or Main Spring was still being used as a source of drinking water but because of on-going concerns about the safety of the water for human consumption, and sufficient water being available from the new schemes like Steenbras and Wemmershoek, a decision was taken to discontinue using the Stadsfontein for drinking water purposes. Since then most of the water joined the stormwater to the sea, until 2010 when the City recommenced using the water for irrigation at Green Point Stadium and the Commons. City of Cape Town faces a number of water supply challenges. These include managing the ever increasing demands on the current water supply. The City of Cape Town Springs Study was born from this 2001 Water Demand Management study and it aims primarily to examine the possibility of using spring water as an alternative source of water for non-potable supply. Of these, the springs which hold the most potential for use are found in two areas - the CBD area of Oranjezicht, home to the Field of Springs

Abstract

Cadmium is a highly mobile and bioavailable non-essential element that is toxic to plants, and is an animal and human carcinogen (affecting the kidneys and bones in vertebrates). Since the late-1970s the effects of cadmium on the environment have become a global issue of concern, and many countries have conducted evaluations on the exposure of their populations to cadmium in phosphate fertilizer (a major non-point source of anthropogenic cadmium). A scoping project, funded by the Water Research Commission, aimed to review cadmium contamination of South African aquifer groundwater systems (predominantly) via phosphate fertilizer use. Topics reviewed included fertilizer composition and types, metal speciation, metal mobility in soil and groundwater systems, metal bioavailability, health and environmental effects, and local South African contamination case studies. A preliminary study site, namely the greater Hermanus region, was identified for trace metal and groundwater quality studies (which incorporated urban and agricultural areas in various hydrogeological settings). Hermanus was selected due to: 1) the discovery of cadmium concentrations of 20 ?g/l (in comparison to the SANS 241-1:2011 cadmium limit of 3 ?g/l) in a golf estate irrigation borehole, during drilling and test-pumping of the borehole at the end of 2012

Abstract

At a regional scale, groundwater recharge is often calculated using surface water models. Precipitation and surface water runoff are easier to measure than groundwater recharge, and evapotranspiration can be estimated with relative accuracy using indirect methods. In modelling, surface water measurements can be used for calibration, and groundwater is the residual term in the water balance of the catchment. This can give a good indication of regional trends, but provides limited scope for the accommodation of groundwater system characteristics and recharge processes. Recently, much research has been focused on the interaction of surface and groundwater models. The coupling of physically based surface and ground water models allows for calibration of the model using both surface and groundwater data while providing scope for improved insight into the processes which define the interaction of groundwater with the rest of the water cycle. For example: stream discharge, interflow, preferential flow through the unsaturated zone and interaction with surface water retained in dams and wetlands. One such model is GSflow (United States Geological Survey), which we are applying to the Upper Vaal Catchment. This model integrates the surface water model PRMS (Precipitation-Runoff Modelling System) with MODFLOW (Modular Groundwater Flow model). The model is initially being calibrated at quaternary catchment scale, starting with the surface water components and later adding the groundwater system. The quaternary catchment is subdivided into smaller, topologically defined hydrological response units. This scaling allows for a better understanding of how well the characteristics of the units are represented in the physical processes incorporated into the model, so that ultimately the sensitivity analysis can incorporate these processes. The results will be compared to current work on recharge being carried out using GRACE data and previous work done in the same area. Once the entire model has been calibrated, there will be scope to calculate future scenarios, allowing for climate and land-use changes. A brief overview of existing work as well as methods and initial results and sensitivity analysis will be presented.

Abstract

Water scarcity is a growing issue in South Africa. The consumption of water is rising and as such, water is becoming a scarce and valuable resource. Given the circumstances that South Africa is facing, improving the use of ground water could help tackle water scarcity in South Africa. Groundwater has been an important source of water and it can bring socio-economic benefits if properly used. Studies have proved that groundwater resources play a fundamental role in the security and sustainability of livelihoods and regional economies throughout the world. However, in South Africa, groundwater still remains a poorly managed resource and this hinders socio-economic development. This paper examines the current state of ground water management in South Africa. The paper also examines how ground water in South Africa is currently allocated and used, and explores some of the consequences of current water management arrangements. {List only- not presented}

Abstract

A groundwater study at Middelburg Colliery was completed with the emphasis on the investigations into water balances on a rehabilitated coal mining environment. Water balance calculations and water scheduling for collieries in Mpumalanga have become important facets of mine planning over the past years. Opencast mining involves the blasting and removal of rocks overlying the coal layer, which is removed completely. The overburden is then replaced (backfilled) and covered with soil and the terrain is rehabilitated. Rainwater penetrating through the soil into the backfill may become acidic by pyrite and sulphides in the backfill material and ultimately decants on the surface. Decanting generally commences a decade or more after mining ceases. Opencast mining impacts the natural groundwater regime and radically alters the nature of groundwater-surface water interactions. The Department of Water Affairs and Forestry in South Africa requires that mines minimise the release of their polluted water. A groundwater balance is the numerical accounting of the annual recharge to a groundwater resource. It can further be described as a quantitative assessment of the total water resources of a basin over a specific period of time. In a groundwater development program, such a budget is necessary to efficiently manage and utilize the resource. Many of the parameters that determine recharge to an aquifer are measured directly and some are computed from hydraulic characteristics and measured field data. The Middelburg Mine Services has been experiencing excess water problems in past years. Because of the lack of space and the concerns of decanting of mine water out of the rehabilitated pit, it was suggested that mine water treatment should be considered. Geohydrological models were created to determine the decant positions and water volumes for the rehabilitated area. The size of the water treatment plant can then be determined using the calculated decant volumes and positions.