Conference Abstracts

All Abstracts were presented at the Groundwater Conferences

Displaying 701 - 750 of 795 results
Title Presenter Name Presenter Surname Area Conference year Sort ascending Keywords

Abstract

POSTER A quick analysis of spring water quality was conducted in four neighbouring villages, namely Vondo, Matondoni, Maranzhe and Murangoni in Thohoyandou town under the Thulamela Local Municipality (TLM) of the Vhembe District Municipality (VDM). For the purposes of this study these villages will be termed VMMM villages. A study on the spring water quality of VMMM villages was conducted by the CSIR to determine whether the natural quality state of the spring water used by the surrounding communities was suitable for drinking purposes without pre-treatment. From the four springs that were identified in the VMMM villages, namely Tshali (S1), Ramufhufhi (S2), Tshinwela (S3) and Tshivhase (S4), water samples were taken for the quality analyses in the laboratory. The results indicated that S2 and S4 had a high coliform count of 35 and 600 per 100 ml, respectively), that is above  10  counts  per  100 ml.  In  springs  S2  and  S4  the  total  coliform  count  also  displayed  the presence of E.coli (6 and 310 per millilitre, respectively)  – E.coli should not be detected at all according to SANS standard limits (2011). While all other parameters were within standard limits (SANS 241, 2011), it was also interesting to note that both S3 and S4 had a problem of high turbidity (1, 6 and 105 NTU, respectively) compared to 1 NTU which is the standard limit (SANS 241, 2011). These results showed that although these communities relied on groundwater in the form of springs for drinking purposes, unmonitored use of these resources may be a health hazard that has a potential to  result  in disease outbreak  and  unprecedented  deaths. While  groundwater through springs is considered natural, increased activity around the source due to human activity and interference by domestic animals, these sources may be rendered unsafe for drinking purposes without prior treatment. Therefore, there is need for local authorities to put measures in place to monitor water resources considered indigenous and traditional to the communities, especially in areas where these resources have become the main source of water supply for drinking purposes.

Abstract

The Palla Road well-field is located in the Central District of Botswana approximately 160 km from Gaborone and 50 km from Mahalapye. The aim of this project was to review and update the existing groundwater model developed in the late 1990s of the Palla Road well-field in order to assess the viability of long-term groundwater abstraction due to the increasing water demands in the region. The  main  hydrogeological  units  recognised  in  the  project  area  comprise  of  aquifer  systems developed in the Ntane Sandstone Formation and formations of the Middle Ecca Group with minor aquifers developed in Mosolotsane Formation and the Stormberg Basalt. The finite-difference model boundary covers an area of 3 702 km2  and was set-up as a three-dimensional semi-uniform grid comprising of four layers. Eight recharge and 14 hydraulic conductivity zones in accordance with the geological  model  were  distinguished.  Steady  state calibration  was  accomplished  by  varying the hydraulic conductivity values, while keeping the recharge rates constant in order to achieve a unique solution. Transient calibration of the model covered three larger stress periods namely: (1) initial condition (pre-1988), (2) abstraction period (1988 to 2012) and  (3) predicted model simulations (2013 to 2036).

The calibrated groundwater flow model was used to assess the impacts associated with  the  proposed  abstraction  scenarios  for  the  Palla  Road  and  Chepete  well-fields  with consideration  of  potential  cumulative  impacts  due  to  the  Kudumatse  well-field.  Three  basic scenarios comprising certain sub-scenarios based on the future water demand for the Palla Road and Kudumatse region were considered. The model simulations show that the abstraction scenario 2a, namely simultaneous abstractions from the Chepete/Palla Road and Kudumatse well-fields, poses a risk to the sustainability of downstream water resources. The maximum simulated drawdown in the central and  southern parts of the Palla Road well-field  reach 14 m after six years of  pumping. Although outflow diminishes after a six-year period, it is restored to approximately 80-90% after the simulated recovery period. The presented 3-D multi-layer model can be used as a tool to determine the optimal abstraction rates while giving cognisance to the sustainability of the resource.

Abstract

POSTER All groundwater is vulnerable to contamination, and natural in homogeneity in the physical environment results in certain areas being more vulnerable to contamination than others. Inherent in the agricultural, domestic and industrial sectors of Pietermaritzburg, is the generation of contaminants which, upon reaching the aquifer, result in the deterioration of the quality of groundwater, thus resulting in the water no longer being fit for its intended use. The DRASTIC method is used to calculate the groundwater vulnerability of a 670 km2 region, including the city of Pietermaritzburg. The suggested ratings of each parameter are scrutinised and adapted, according to their relevance to the region and according to known geological occurrences. The use of this method enables the user to generate a regional scale vulnerability map of the groundwater in Pietermaritzburg. The vulnerability map generated has the ability to effectively highlight vulnerable areas to groundwater contamination, which is of critical importance in correct land-use planning, as well as in indicating areas of particular concern, where further detailed investigations are needed. The results of such an assessment are used as an input, together with a contamination inventory to assess the potential risk of groundwater pollution in a groundwater risk map. Furthermore, the result informs local decision-makers and enables proactive prevention of groundwater pollution, in accordance with section 13 of the 1998 National Water Act. The intrinsic vulnerability of the Pietermaritzburg region was found to range from low to very high. The area found to be highly vulnerable is the region northeast of Springbank which requires investigation at a local scale.

Abstract

Work is being conducted in Limpopo province following a large volume release of petroleum hydrocarbons that took place from a leaking underground pipeline, resulting in significant groundwater contamination. This is considered to be the largest petroleum hydrocarbon release recorded to date in South Africa. The leak took place for 15 years before it was discovered 13 years ago in 2000. From the pressure tests that were performed, 10-15 ML of A-1 Jet fuel is considered to havbeen  released  to  the  subsurface.  Product  bailing was  the  first method  employed  for  the recovery of the free product, and was later replaced with a P&T system which was considered to be more effective.

The village located about 6 km to the north of the spillage depends mostly on groundwater. This paper presents a progress update of works that have been conducted in support of developing a conceptual model which aims to determine the areal extent of the plume.

Abstract

The groundwater quality component of the Reserve serves as guidance for groundwater quality requirements when assessing water use license applications. The Reserve is the quantity and quality of water required to satisfy the basic human needs and protect the aquatic ecosystem in order to ensure ecologically sustainable development and use of water resources. This component provides guidance when assessing the suitability of groundwater for drinking purposes. The current groundwater quality was based on the Quality of domestic water supplies, assessment guide (vol. 1,2nd   ed.,  1998).  The  parameters  that  were  assessed  in  the  current  template  include  chemicalssodium, magnesium, calcium, chloride, sulphate, nitrate and fluoride; and physical parameters: pH and  electrical  conductivity.  The  above-mentioned  ions  cater  fomost  water  uses  applied  for, whereas the revised template will also include microbiological (escherichia coli), toxics (zinc, manganese, iron, cadmium, cobalt and copper) for local government and mining commodity/by- product specific water use applications. The current water quality basic human needs values will also be replaced with SANS 241 (2011) guidelines. Inputs and suggestions are therefore requested from various end users/stakeholders.

Abstract

The study on estimation of groundwater recharge was done in Grasslands Catchment, about 70 km south-east of Harare, Zimbabwe. The catchment is underlain by Archean Granitic rocks intruded by dolerite  dykes/sheets  and  form  part  of  the  Basement  Complex.  The  catchment  is  a  stream headwater wetland, at the source of Manyame River. The catchment comprises an upland region or interfluves of area 2.12 km2 and a dambo area of 1.21 km2. The study focused on the assessment of temporal and spatial variability of moisture fluxes based on solute profiling, and groundwater recharge and investigations of moisture transport mechanisms. The methodology involved the use of  both  hydrometric  and  hydrochemical  techniques.  Groundwater  recharge  rates  and  moisture fluxes were calculated using a chloride mass balance technique in comparison to the hydrograph separation technique. Groundwater recharge was estimated to be 185 mm/year using the chloride mass  balance  and  215 mm/year  using  the  hydrograph  separation  technique.  Mechanisms  of recharge were investigated using the bimodal flow model that comprised of diffuse flow and preferential flow. The results revealed that preferential flow contributes up to 95% of the recharge in the interfluves, whilst diffuse flow contributes up to 5% of the total recharge. The results reveal that the groundwater hydrograph technique results are in agreement with the chloride mass balance method. The study illustrated how routine observations can improve process understanding on groundwater recharge mechanisms. The techniques are not expensive, are easy to use and can be replicated elsewhere depending on availability of data.

Abstract

Evidence suggests that physical availability of groundwater may be only one of many factors in determining whether groundwater-based rural water supply schemes in South Africa are reliable or "sustainable". Other factors include budgetary constraints, community preferences, policy decisions, operation and maintenance procedures, and the availability of skilled staff. These factors and others combine to create "complex problems" around the issue of rural water supplies that require a multidisciplinary approach if they are to be effectively resolved. This work is an on-going part of Water Research Commission Project K5/2158, “Favourable Zone Identification for Groundwater Development: Options Analysis for Local Municipalities”, due to be completed in March 2014.

Abstract

The Deep Artesian Groundwater Exploration for Oudtshoorn Supply (DAGEOS) Project is culminating in development of the Blossoms Well-field (C1 Target Zone), about 20 km south of the town. The target Peninsula Aquifer is located at depths >300 m below ground level, geopressured to ~800 kPa (8 bar) artesian head. Each production well has to be uniquely designed for site-specific hydrogeological, hydrochemical and aquifer hydraulic conditions. Hydrostratigraphy rather than stratigraphy must inform the final well design. It is a recipe for unnecessary expense and deleterious consequences for aquifer management, to design and commence the drilling of wide-diameter production wells without the data and information provided by necessary exploration and essential pilot boreholes, yielding broader hydrogeological insights.

During discovery exploration at the C1b Target Site Area (TSA), drilling of a 715 m-deep  diamond-core exploration  borehole (C1b2)  was essential  for  the  proper  siting and  safe design  of  a  production  well  (C1b3).  Following confirmation  of  the  artesian nature  of  the  Peninsula Aquifer, the C1b2 borehole was equipped for monitoring, prior to the drilling of the nearby (~25 m distant) C1b3 production well, which was piloted with a core borehole down to a low level (~290 m) within the Goudini Aquitard, where it became marginally artesian and was then plugged and sealed. This pilot borehole was reamed with wide-diameter percussion tools to a depth where casing could be firmly cemented within the Goudini, above a solid, relatively unfractured zone. The final stage of drilling into the Peninsula Aquifer, using the Wassara water-hammer method, was thereafter continuously monitored from the C1b2 site, and the subsequent recovery history of C1b3 is comprehensively documented. The DAGEOS   drilling   and   deep-groundwater   monitoring   provides   significant   experience   in   solving technological problems likely to be encountered in the future development of shale-gas in the main Karoo basin. The confined, artesian aquifer behaves very differently to other, conventional groundwater schemes and requires a different management approach that focuses on managing the artesian pressure within the basin  and  its  response  to  abstraction.

The  potential  adverse  influences  of  high  and/or  extended abstraction on the Peninsula Aquifer may be divided into two general categories: 1) depletion or degradation of the groundwater resource, and 2) environmental or ecological consequences. Depletion in the case of a confined aquifer refers to depletion in storage capacity due to non-elastic behaviour. Environmental/ecological impacts of groundwater extraction arise only when the ‘radius-of-influence’, defined by the distance from the centroid of a well-field to the perimeter of the cone of depression in the ‘potentiometric surface’ (surface of pressure potential in the aquifer), reaches recharge and or discharge boundaries. The new Oudtshoorn Groundwater Scheme affords an opportunity to stage a transition from an increasingly risky reliance on surface water that is prone to severe reduction through climate change, to a deep groundwater resource that is capable of acting as a sustainable buffer against water-scarcity through drought intervals that may endure over decades rather than years, and can be operated without electricity supply by utilising the artesian pressure in the aquifer. This approach was demonstrated in a 3- month artesian flow test during 2009.

 

Abstract

This study explores some of the principle issues associated with quantifying surface  water and groundwater interactions and the practical application of models in a data scarce region such as South Africa. The linkages between the various interdependent components of the water cycle are not well understood, especially in those regions that suffer problems of data scarcity, and there remain  urgent  requirements  for  regional  water  resource  assessments.  Hydrology  (both  surface water and groundwater hydrology) is a difficult science; it aims to represent highly variable and non- stationary processes which occur in catchment systems, many of which are unable to be measured at the scales of interest. The conceptual representations of these processes are translated into mathematical form in a model. Different process interpretations, together with different mathematical representations, result in the development of diverse model structures. These structural uncertainties are difficult to resolve due to the lack of relevant data. Further uncertainty is introduced  when  parameterising  a  model,  as  the  more  complex  the  model,  the  greater  the possibility that many different parameter sets within the model structure might give equally acceptable results when compared with observations. Incomplete and often flawed input data are then used to drive the models and generate quantitative information. Approximate implementations (model structures and parameter sets), driven by approximate input data, will necessarily produce approximate results. Most model developers aim to represent reality as far as possible, and as our understanding of hydrological processes has improved, models have tended to become more complex. Beven (2002) highlighted the need for a better philosophy toward modelling than just a more explicit representation of reality and argues that the true level of uncertainty in model predictions  is  not  widely  appreciated.  Model  testing  has  limited  power  as  it  is  difficult  to differentiate  between  the  uncertainties  within  different  model  structures,  different  sets  of alternative parameter values and in the input data used to run a model. A number of South African case studies are used to examine the types of data typically available and explore the extent to which a model is able to be validated considering the difficulty in differentiating between the various sources of uncertainty. While it is difficult to separate input data, parameter and structural uncertainty, the study found that it should be possible to at least partly identify the uncertainty by a careful examination of the evidence for specific processes compared with the conceptual structure of a specific model. While the lack of appropriate data means there will always be considerable uncertainty surrounding model validation, it can be argued that improved process understanding in an environment can be used to validate model outcomes to a degree, by assessing whether a model is getting the right results for the right reasons.

Abstract

The determination of a sustainable groundwater yield is a complex and challenging task. There is a high degree of uncertainty associated with most aquifer parameters such as recharge from rainfall and aquifer storativity, especially in  fractured aquifers. This leads  to  analysts often taking a  very  conservative and  risk  adverse approach  in  determining  the  sustainableyield  for  boreholes.  The  problem  with  this  approach  is  that groundwater can be considered as impractical or not an option, due to the low and conservative yields. Potential well-fields also become too expensive to develop. The concept of sustainability does not only cater for the environment, but also for people (social) and the economy (business). A popular method to determine groundwater sustainability is the groundwater balance (also known as the groundwater budget) method. This method has come under scrutiny as it is proposed that capture zone method is a more conservative and technically correct approach. Two of the most important parameters in determining long-term borehole yield, namely recharge and storativity, are unknown and unknowable at the time of well-field development. At best, qualified guesses can be made with regard to these two parameters. This makes the capture method impractical as boreholes have to be drilled and tested first and capital spent before any planning can be done. 

In this paper, it was shown that the risk adverse approach in determining borehole yield will result in the most expensive groundwater development option. The principle of sustainability requires that environmental, social and economic considerations be taken into account. By following a risk adverse approach, which would be the most expensive, the principle of sustainability is violated and it cannot be claimed that the borehole yield is sustainable. Due  to  the  exponential relationship between  risk  and  cost,  a  no-risk  approach  would  be infinitely expensive. It was shown that due to the uncertainties, it is actually impossible to determine the sustainable yield of a borehole. The objective should rather be to develop a sustainable groundwater management plan. This can be achieved by following a systems management approach based on the minimum groundwater balance. The minimum groundwater balance approach makes use of, for example, hydro census data to determine a minimum groundwater balance for a system of aquifers based on recharge at a minimulevel of assurance, for example lower 95th percentile, rather than making use of the mean annual precipitation (MAP). The potential effects of storativity are neglected at this stage. The systems management approach was applied on a case study to demonstrate the application where some risk was taken for a limited period of time while monitoring takes place. Proactive warning systems would alert decision-makers when to develop new aquifers which are predefined, based on the minimum groundwater balance method. The difference is that in the case of the risk adverse approach, should it come to light that the recommended abstraction rates were wrong in the sense that it is too low, the capital is spent and cannot be recovered. In the case of the systems approach, where slightly risky abstraction rates are recommended for a limited period of time, additional well- fields can be developed well in advance, before any negative environmental impacts can occur.

Abstract

The possibility of large reserves of shale gas underlying the Karoo and their exploitation has focused attention on the groundwater resources and aquifers of this region. Much is known about the relatively shallow aquifers (<300 m) which supply many local municipalities and farmers with water for domestic, stock and irrigation use (mostly from boreholes <150 m in depth). Conversely, little is known about the deeper formations (>500 m) and associated groundwater occurrences and their possible interconnection to the shallow aquifer systems. This paper covers a desk study of the southern Karoo, mostly above the Great Escarpment, carried out by a group of hydrogeologists/geochemists with a cumulative experience of about 250 years. The main consideration at this stage has been the collation and analysis of existing information, using GIS, conceptualisations, and identification of knowledge gaps.

A Karoo Groundwater Atlas was published in 2012 and Volume 2 has been released at this conference, which present a summary of the main analyses. Borehole yield, recharge and quality in the shallow aquifer tend to improve, and water levels become shallower, from west to east, associated with higher rainfall and increased percentage of dolerite and sandstone. Aquifer yield, quality, lithology and presence of dolerites constitute 60% of a groundwater attributes ratings classification; 54% of the study area has a high rating. Twenty four percent of the study area has a high vulnerability rating. Knowledge of the characteristics of groundwater associated with the deeper formations is restricted to a few thermal springs and sparse data from some deep hydrocarbon exploration wells. Weak artesian flows were recorded from two such wells in the Dwyka Group below the Great Escarpment, with Total Dissolved Solids of up to 10 000 mg/L and temperatures of up to 77 oC, from depths of 2 347 to 3 100 m. Further work and cooperation with other researchers/institutions is on-going and planned to fill in knowledge gaps and assess the risks to groundwater of shale gas exploration.

Abstract

Groundwater in South Africa is an essential source of potable water for rural communities, farms and towns. Semi-arid conditions of South Africa, a growing population and surface water resources almost entirely being exploited to their limits, increase  the demand for groundwater resources. Therefore,  the  relation  between  the  geology  and  geohydrology  of  South  Africa  becomes  an important tool in locating groundwater resources that can provide sustainable quantities of water for South Africans. A document was therefore compiled, providing valuable geohydrological information  on  the  geological  formations  of  the  whole  of  South  Africa.  The  information  was gathered by means of interviews with experienced South African geohydrologists and reviewing of reports and articles of geohydrological studies. The geohydrological characteristics discussed include rock/aquifer parameters and behaviour, aquifer types (primary of secondary), groundwater quality, borehole yields and expected striking depths, and geological target features and the geophysical method  used  to  locate  these  targets.  Due  to  the  fact  that  90%  of  South  Africa’s  aquifers  are classified as secondary aquifer systems, groundwater occurrence within the rocks of South Africa is mainly controlled by secondary fractured systems; therefore, understanding the geology and geological processes (faulting, folding, intrusive dyke/sills and weathering) responsible for their development and how they relate, is important. However, the primary aquifers of South Africa (Coastal Cenozoic Deposits) should not be neglected as these aquifers can produce significant amounts of groundwater. Drilling success rates and possibility of striking higher yielding boreholes can be improved dramatically when an evaluation of the structural geology and geohydrological conditions of an area together with a suitable geophysical method is applied. The ability to locate groundwater has been originally considered (even today) a heavenly gift and can be dated back to the Biblical story of Moses striking the rock to get water: “behold, I will stand there before thee there upon the rocks thou shalt smite the rock and there shall come water out of it” (Exodus 17:6).

Abstract

Groundwater is the water that is found beneath the surface of the ground in a saturated zone (Bear 1979). Groundwater contamination refers to the groundwater that has been polluted commonly by human activities to the extent that it has higher concentrations of dissolved or suspended constituents. The scale of the potential supply of groundwater from the Cape Flats Aquifer Unit (CFAU) is very significant due to the increase of the population in Cape Town that leads to limited water resources (Maclear 1995). Groundwater contamination is a threat in the Cape Flats. This is because sand is more susceptible to pollution as a result of urbanisation, industrialisation, intense land use area for waste disposal and agricultural activities (Adelana 2010). The aim of this paper is to evaluate groundwater contamination and assess possible prevention and treatment measures in the CFAU. Pumping tests were done in UWC site in Borehole 5 (pumping borehole) and Borehole 4 (observation borehole) for six hours; three hours was for the pumping and the other three hours for recovery. This was done in order to see how the aquifer recovers after pumping. Water samples were also taken and analysed in the lab. This was done to find the type of contamination, whether it is degradable or non-degradable. The Borehole 5 drawdown plot is showing a straight line. This suggests a linear flow and that there is no confining bed beneath. This is because straight lines are showing the Cooper-Jacob type curve, which is for unconfined aquifers. The curve of Borehole 4 can be fitted to a Theis-type curve. This suggests a radial flow pattern indicating homogeneous characteristics in the deeply weathered zone and that there is a confining bed beneath. This is because aquifers responding in the same manner as the Theis-type curve, are confined aquifers (Hiscock 2005).The groundwater samples are showing a TDS range of 260 to 1 600 mg/l. This could be the result of the waste water treatment plant that is near UWC and the industries that are near the airport and at Bellville South. In conclusion, the geology of the CFAU is very susceptible to groundwater contamination, which is due to agricultural, industrial and human activities.

Abstract

Groundwater  is  a  reliable  freshwater  resource.  Its  location   underground  prevents  it  from evaporative  forces.  Thus  it  serves  as  storage  of  most  of  the  world’s  liquid  fresh  water.  Being enclosed in the ground it is not also easily contaminated. Since groundwater can be used wherever it exists without costly treatments, there is over-dependence on the resource. Though in the past it was mainly used by rural dwellers for domestic water supply, presently, due to effects of climate change on surface water resources, pressures of population growth leading to expansion of towns and cities, groundwater is also supplied for agriculture and industrial purposes. But, the resulting effect from these additional users is the vulnerability of groundwater resources to reduction and pollution. Its importance in sustaining livelihood and development has been highly credited and its management  is  looked  upon  as  a  prerogative.  To  enhance  groundwater  management  in  the Sandveld, a qualitative content analysis approach was used to evaluate six factors considered to be highly needed in groundwater management. This background was used to find out how institutional arrangement in South Africa facilitates or constraints groundwater management in the Sandveld, a highly groundwater dependent area in the West Coast of the Western Cape. The results showed that all  six  factors  are  present,  but  three  facilitate  groundwater  management  while  three  others constrain management. The community involvement which ranked first, is deficient. Thus, institutional weaknesses that need to be strengthened have been identified.

Abstract

Unconventional gas mining is a new and unprecedented activity in South Africa that may pose various risks to groundwater resources. According to legal experts, South Africa does not currently have the capacity to manage this activity effectively due to various lacunae that exist in the South African legislation. The possible impacts of unconventional gas mining on groundwater, as well as governance strategies that are used in countries where unconventional gas mining is performed; have been analysed and will be discussed. Based on possible impacts and strategies to manage and protect groundwater internationally, possible governance options for the management of South Africa’s groundwater resources are proposed.

Abstract

Variability in both rainfall and raw water demands at South African mines and lack of accurate predictive planning tools often leads to water shortages or spillages of excess dirty water. The demand varies due to changing production rates, scheduled and unscheduled maintenance, while available water resources are greatly influenced by droughts and untimely storm events. Using averages in static water balances or planning for “worst case scenarios” by increasing storm water capacity or securing larger volumes from external sources “for in case”, is expensive and could still be inadequate.

A dynamic simulation model can integrate all the variables above with available ground- and surface water resources. Groundwater is  often underestimated as  a  source.  A  simulation model can  test  strategies to optimise its role before expensive dams or pipelines are considered.

In the case studies presented, Arena simulation software (from Rockwell) are used with hourly time steps to dynamically simulate water flows/levels, evaporation, seepage and rainfall runoff. All flows and dam levels are recorded to Excel for statistical analysis after simulation runs. To calculate the significance of overflow events and maximum demands the model runs multiple iterations which render specific confidence intervals for results, for example a 95% confidence level that a specific dam will not overflow more than once during the life of mine. Models may span several shafts, concentrator plants and smelter complexes. One model integrated over 1 000 flows and 75 dams with respective flow logic on the backdrop of a Google map of operations. Highlights of recent case studies include: 

  • Groundwater from shallow anthropogenic aquifers greatly reduced external raw water requirements.
  • This also prevented the clean water from overflowing into the underground workings where it is then pumped from depth as dirty water. 
  • Artificial recharge of an aquifer with sporadic excess surface water increased the groundwater in storage that was used as a buffer for drought periods. 
  • Optimised models proved that external raw water requirements and overflows into the environment could be significantly reduced and in some cases eliminated.

A dynamic water balance simulation model integrates business components with all related flows and storages and is the best tool available to accurately predict water resource demands and overflows to the environment. It enables the testing and optimization of water management strategies long before capital is spent and enhances the understanding, buy-in and decision support for all affected parties.

A picture is worth a thousand words... A (good) simulation is worth a thousand pictures!

Abstract

Accurate parameter estimation for fractured-rock aquifers is very challenging, due to the complexity of   fracture   connectivity,   particularly   when   it   comes   to   artesian   flow   systems   where   the potentiometric  is  above  the  ground  level,  such  as  semi-confined,  partially  confined  and  weak confined aquifers in Table Mountain Group (TMG) Aquifer. The parameter estimates of these types of aquifers are largely made through constant-head and recovery test methods. However, such tests are seldom carried out in the Table Mountain Group Aquifer in South Africa due to the lack of a proper testing unit made available for data capturing and an appropriate method for data interpretation. 

An artesian borehole of BH-1 drilled in TMG Peninsula Formation on the Gevonden farm in Western Cape Province was chosen as a case study. The potentiometric surface is above the ground level in the rainy season, while it drops to below ground level during the dry season. A special testing unit was designed and implemented in BH-1 to measure and record the flow rate during the free-flowing period, and the pressure changes during the recovery period. All the data were captured at a function of time for data interpretation at later stage. 

Curve-fitting software developed with VBA (Visual Basic Application) in Excel was adopted for parameter estimation based on the constant-head and recovery tests theories. The results indicate that a negative skin zone exists in the immediate vicinity of the artesian borehole in Rawsonville, and the  hydraulic  parameters  estimates  of  transmissivity  (T)  ranging  from  6.9  to  14.7 m2/d  and storativity  (S)  ranging  from  2.1×10-5   to  2.1×10-4   appear  to  be  reasonable  with  measured  data collected from early times. The effective radius is estimated to be 0.5 to 1.58 m. However, due to formation losses, the analytical method failed to interpret the data collected at later times. Consequently the analysed results by analytical solution with later stage data are less reliable for this case. Numerical modelling is proposed to address the issue in future.

Abstract

In recent years there is an increased awareness of hydrocarbon contamination in South Africa, and the need for remediating sites affected by these contaminants. Hydrocarbon contamination of groundwater can be caused by a large variety of activities at industrial, mining or residential areas. Once these contaminants are discovered in groundwater where it poses risks to human health and/or the environment, remediation is often required. Remediation of groundwater has become a booming industry for groundwater practitioners and often there is an attitude of more sophisticated and expensive solutions are better. This paper will show that this attitude is not always the best solution, but rather recommend an approach where a combination of low cost/low maintenance system need to be investigated and applied to reach clean-up goals. Determination of natural attenuation potential and on-going monitoring forms an integral part of this type of solution.

Abstract

Unconventional gas mining is a new and unprecedented activity in South Africa that may pose various risks to groundwater resources. According to legal experts, South Africa does not currently have the capacity to manage this activity effectively due to various lacunae that exist in the South African legislation. The possible impacts of unconventional gas mining on groundwater, as well as governance strategies that are used in countries where unconventional gas mining is performed; have been analysed and will be discussed. Based on possible impacts and strategies to manage and protect groundwater internationally, possible governance options for the management of South Africa’s groundwater resources are proposed

Abstract

The aim of this study was to determine the geohydrological status of the aquifer within the boundaries of the Vanrhynsdorp Water User Association with emphasis on the central catchment, E33F. This will assist the Department of Water Affairs with the introduction of compulsory groundwater-use licensing and empowerment of the Vanrhynsdorp Water User Association to manage the resource. In this study emphasis was given to the determination of the water balance and  groundwater  reserve  of  the  central  catchment  and  the  designing  of  a  representative groundwater monitoring network. A literature study of five projects conducted since 1978 was done. Comparisons were made between the data and results of these studies. All the historical data from these studies, as well as the data from the current monitoring programme up until December 2012, were put together and analysed. A conceptual model and groundwater reserve determination, as well as a representative monitoring network, were produced. The study showed a general decline in groundwater levels over a 34-year period. It also showed an increase in rainfall over the last 20 years. Based on the reserve determination and the declining groundwater level in spite of increased rainfall and thus recharge, it was concluded that over-abstraction of groundwater in the study area is taking place. It is recommended that compulsory licensing should be put in place as soon as possible and  that  no  additional  groundwater-use  licences  should  be  granted  in  the  study  area.  The installation  of  flow  meters  on  all  production  boreholes  should  be  stipulated  in  the  licensing condition. This will assist the monitoring and regulation of groundwater abstraction volumes.

Abstract

Work is being conducted in Limpopo province following a large volume release of petroleum hydrocarbons that took place from a leaking underground pipeline, resulting in significant groundwater contamination. This is considered to be the largest petroleum hydrocarbon release recorded to date in South Africa. The leak took place for 15 years before it was discovered 13 years ago in 2000. From the pressure tests that were performed, 10-15 ML of A-1 Jet fuel is considered to have  been  released  to  the  subsurface.  Product  bailing was  the  first method  employed  for  the recovery of the free product, and was later replaced with a P&T system which was considered to be more effective.

The village located about 6 km to the north of the spillage depends mostly on groundwater. This paper presents a progress update of works that have been conducted in support of developing a conceptual model which aims to determine the areal extent of the plume.

Abstract

Acid-mine drainage (AMD) has received considerable media coverage in South Africa as of late. This have caused a considerable increase in researches, most of them with emphasis on decanting of contaminated water from the old gold mines in Witwatersrand basins and fewer on mine residue contamination from coal and gold mines in the Mpumalanga Province. The paper outlines results of ground geophysical surveys that were carried out along the perimeter of two mine residual deposits (dumps) in the Barberton Greenstone Belt, Mpumalanga Province. The aim of the study was to generate a  3D geoelectric model of the subsurface showing possible acid-mine drainage contaminant pathways. Two geophysical methods, namely Frequency Domain Electromagnetic Profiling (FDEM) and Electrical Resistivity Tomography (ERT) were applied in order to investigate the variation of electrical conductivity in the subsurface. The ERT method was done over frequency domain electromagnetics anomalies.

FDEM electrical conductivity values ranging between 40 mS/m to 60 mS/m were considered as anomalous in that geological terrain. These areas were then surveyed by the ERT method to check the depth extent of these FDEM anomalies. On the resistivity section, between station 40 m and 80 m of Dump 1 – ERT1, a discontinuity in the bedrock was identified. The area could act as a pathway for contaminants to flow from the dump to groundwater. The FDEM survey identified an area with high conductivity values to the north of Dump 1. The ERT results also showed a shallow plume at 30 m depth which is consistent on two parallel sections on Dump 1. The area could be a possible AMD pathway of a mine dump residue to a Komati tributary on the north. The bedrock is generally characterised by high resistivity values; a break in the bedrock exists on this high resistivity zone on ERT 6. This break could be a fault zone which can act as possible pathway of (AMD) from a mine dump residue to a shallow aquifer.

Potential contaminant recharge pathways were delineated using geophysical, electrical and electromagnetic methods. Potential groundwater recharge pathways and sub-vertical low resistivity zones with values <100Ohm.m   were   delineated   using   the   ERT   method.   Investigation   of   contaminant   plume   migration   is recommended over the anomalies that were generated from geophysics data in the Barberton areas. New technologies (artificial neural networks (ANN), fuzzy logic, etc.) combined with laboratory studies is recommended for development of a software platform that accepts 3D geoelectric data (present study), constrained with geology, geochemistry (soil and water), hydrology and hydrogeology data.

Abstract

Characterisation of fracture positions is important when dealing with groundwater monitoring, protection and management. Fractures are often good conduits for water and contaminants, leading to  high  flow  velocities  and  the  fast  spread  of  contaminants  in  these  conduits.  Best  practice guidelines related to groundwater sampling suggest that specific depth sampling with specialised bailers or low flow purging are the preferred methodologies to characterise a pollution source. These methods require knowledge about the fracture positions and, more importantly, flow zones in the boreholes. Down-the-hole geophysical and flow logging are expensive, complicated and time consuming. Not all fracture zones identified with geophysical logging seem to contribute to flow through   the   borehole.   An   efficient   and   cost-effective   methodology   is   required   for   the characterisation of position and flow in individual fractures. This research reviewed the use of Fluid Electrical Conductivity (FEC) logging to assist with the development of a monitoring protocol. FEC logging  proved  to  be  beneficial  as  it  provided  individual  fracture  positions,  fracture  yields  and vertical groundwater flow directions. FEC logging proved to be fast, cost-effective and practical in deep boreholes. The technique allows the development of a site-specific sampling protocol. The information so obtained assists with the identification of the appropriate sampling depths during monitoring.

Abstract

Currently limited progress is made in South Africa (and Africa) on the protection of groundwater quality. To achieve the objective of water for growth and development and to provide socio- economic and environmental benefits of communities using groundwater, significant aquifers and well-fields must be adequately protected. Groundwater protection zoning is seen as an important step in this regard. Till today, only one case study of groundwater protection zoning exists in Africa. Protection zone delineation can be done using published reports and database data. However, due to the complexity of the fractured rock at the research site, more data are required. This data can be collected by conducting a hydro census and through aquifer tests. An inventory of the activities that can potentially impact water quality was done and aquifer characteristics such as transmissivity and hydraulic conductivity were determined through various types of aquifer testing. Fracture positions were identified using fluid-logging and fracture flow rates were also measured using fluid-logging data. A conceptual model and basic 3D numerical model were created to try to understand groundwater movement at the research site. The improved information will be used to build a more detailed numerical model and implement a trustworthy groundwater protection plan, using protection zoning. The expected results will have applicability to groundwater management in general. The protection plan developed during this project can be used as case study to update and improve policy implementation.

Abstract

The Heuningvlei pipeline scheme was built in the 1980s to supply water to rural communities in a low rainfall area (<300 mm/annum) – Northern Cape Province. In 2008, the Joe Morolong Local Municipality identified the need to refurbish and upgrade the pipeline scheme for socio-economic reasons. The safe yield and water quality information of existing sources supplying the scheme was unreliable. This was investigated by borehole test pumping and water quality sampling, which indicated reduced yields and deteriorating water quality since 1989.

Water demands, which includes supply to communities for domestic use, schools, clinics and stock watering in the Heuningvlei area, was estimated at 2 380 m3/day or 868 700 m3/annum. The potable groundwater  supply  recommended  from  11  existing  boreholes  is  316 937 m3/annum,  leaving  a deficit of 551 763 m3. The aquifers utilised for the existing water supply comprise fractured banded iron formations (BIF) and dolomite bedrock. Kalahari sedimentary and dolomite aquifers to the east of the pipeline scheme contain high saline water not suitable for domestic use.

No surface water sources exist in the area and the feasibility of the socio-economic development project depends on establishing local groundwater resources that would not impact on existing sources. A target area was identified which is approximately 10 km south from the pipeline. This area is covered by the thick Kalahari sediments (up to 130 m) underlain by dolomite bedrock with a potable groundwater balance of 2.3 million m3/a. Both the associated primary (Kalahari) and secondary (Dolomite) aquifers contain potable water. The target area was not investigated in the past due to perceived poor water quality (elevated salinity) conditions, very low (<10 %) borehole exploitability prospect and difficult drilling conditions.

The paper will discuss the importance of recharge estimate and understanding of flow regime at sub-catchment and local scale, use of an airborne magnetic survey in conjunction with ground geophysics, mapping of Kalahari sediment thickness, and successful drilling of exploration boreholes to exploit the deeper Kalahari sedimentary and dolomite bedrock aquifers. The successful development of localised potable water in a low rainfall area made it feasible to implement the Heuningvlei socio-economic development project.

Abstract

Gold mining on the Witwatersrand has started in the late nineteenth century as sporadic open cast mining and ceased in the late twentieth century, leaving a complex network of haulages, tunnels and ultra-deep vertical shafts/sub-vertical shafts. At least three ore bodies (conglomeritic horizons) were mined down to a depth in excess of 3 000 m from surface. Three large mining basins resulted from the mining methodology applied, namely the Western, Central and Eastern (Rand) Basins.

In  the  early  days  of  mining  on  the  Witwatersrand  reefs,  gold  mine  companies  realised  that dewatering of their mine workings is required to secure mining operations at deeper levels and decades of pumping and treatment of pumped mine water followed. As the majority of deep gold mines on the Witwatersrand ceased operations since 1970, the deeper portions of the mine voids became flooded and led to a new era in the mining history in the Witwatersrand.

Rewatering of the mine voids is a combination between excessive surface water ingress generated by surface runoff, and to lesser degree recharge from an overlying fractured and weathered aquifer system (where developed). The flow regime in the mine voids from a scattering of ingress/direct recharge points and single discharge points are complex and is driven by shallow (<100 m) and probably deep (>1 000 m) man-made preferential pathways.

The high concentrations of iron sulphide minerals (pyrite. for example FeS2) content, three percent (by weight), of the mined reefs/backfilled stopes and surrounding waste rock piles/tailings dams mobilised significant levels of sulphates (SO4) and ferrous iron (Fe2+) producing an acidic mine-void water (<3 pH).

Monitoring of the rewatering mine void hydrological regime became necessary following the first acid-mine water decant from a borehole in the West Rand Basin, and the Department initiated a mine-void water table elevation trend and water quality monitoring programme. Results from this monitoring programme will be illustrated and discussed in this paper with some views on the future water quality and discharge scenarios.

Abstract

The National Environmental Management Waste Act, 59 of 2008 (NEMWA) clearly identifies the status and risk of contaminated sites and provides a legislative mechanism for remediation activities to be implemented and controlled. The Draft National Framework for the Management of Contaminated Land (henceforth Framework) provides national norms and standards for the practical implementation of remediation activities in compliance with NEMWA. A soil-screening value (SSV) for the protection of water resources is based on a two-phase equilibrium partitioning and dilution model which includes a dilution factor (DF) and partitioning coefficient (Kd) which converts the water quality guideline to a total soil-screening value. This paper presents a methodology to use soil-specific Kvalues to improve the accuracy of the new South African guideline for contaminated land.

Appropriate Phase 1 screening assessments are important due to the potential consequence it holds. Some uncertainty exists in the Phase 1 screening values due to variability in Kd values for different soil. This study shows that the Kvalues selected for the Framework is not representative of typical South African soils. Cu Kd values exceed the value provided by the Framework in all soils, but are lower that the Framework V Kd value in all soils. For Pb, low clay content weathered soils have lower Kd, but higher clay content soils are up to four orders of magnitude higher that the Kd in the Framework. Furthermore, due to the large variability (three to four orders of magnitude for Cu and Pb) point estimates of a single Kd value cannot be used for all soil types. However, for V only one order of magnitude variation is found. 

A way of addressing the uncertainty would be to determine the water soluble portion during the assessment. This would dramatically increase the certainty with which screening is conducted and could prevent significant inappropriate screening. Additional cost incurred be offset by saving as a result of unnecessary Phase 2 assessments or the reduction of undetected risks that later could impact the environment

Phase 1 screening could also be improved by including soil classification and some basic soil properties in the site assessment and adjusting Kd values, accordingly. Soil properties that can be used are typically clay content, pH and organic matter content. From these properties more appropriate Kds can be estimated for use in setting screening values.

Abstract

The mineral-rich basin of the West African region has vast reserves of gold, diamond as well as iron ore deposits. Throughout the regional geological setting characterised by structural variations and intrusive belts with metamorphic mineral-rich sequences covered by saprolite soils, one common chemical constituent remains a constant in the water reserves. Arsenic is in high concentrations throughout the region with chemical ranges commonly above the various country guidelines as well as international IFC and WHO standards. The aqueous chemical species is associated with arsenopyrite-rich mineralogy of the regional greenstone belts and highly weathered soils.

This conference presentation investigates the natural source of the arsenic through baseline data, as well as the effect of mining on the already high concentrations of arsenic in both the groundwater and surface water. Natural levels of various chemical species in the regional area are already high at baseline level. One of the main research questions is thus whether mining and other anthropogenic activities will have  an impact on the environment or will  the changes to concentrations be so insignificant to allow the ecosystems and water users to continue in their current ways without any effect. Various case studies in Burkina Faso, Liberia, Sierra Leone and other countries have been combined to investigate the arsenic-rich resources of the West African region through groundwater specialist investigative methods with emphasis on geochemical modelling of the fluid–rock and fluid–fluid interactions leading to the aqueous chemical conditions in the region.

Abstract

The increase in awareness of environmental issues and the desire for a cleaner environment by the public has caused mining companies to place greater emphasis on the continuous rehabilitation of harmful effects caused by mining operations. Ongoing rehabilitation is also a requirement of the government departments involved in mining in South Africa. The biggest concern for the relevant government departments is the possible uncontrolled pollution of water resources in the vicinity of mines, after they have closed.

In  the  compilation  of  this  paper,  the  unique  nature  of  the  South  African  situation  has  been considered – this refers to a legally acceptable approach towards current legislation and policies. This study leads to the construction of a logical approach towards mine closure, specifically to understand issues around costs and financial liability. The final product of this approach should ultimately give more clarity on:

the principles followed to identify objectives for mine closure and groundwater assessment;

key steps to follow when assessing site hydrogeology and to determine related impacts, risks, closure costs and liabilities; and

an overview of methods that could be used for the mitigation of polluted aquifers and a brief site-specific application.

Abstract

Artesian boreholes are a common feature worldwide in confined aquifers. However, the hydraulic testing of these boreholes and estimation of aquifer properties from such tests still pose a challenge for hydrogeologists. Common hydraulic tests, such as step-drawdown or constant discharge rate tests  require  a  static water  level  at the  start  of  the  test,  and  the measurement of  drawdown (increasing over time) and abstraction rate (fixed for a period of time). Usually, when undertaking a pumping test in an artesian borehole, the drawdown is measured from ground level, and the drop in hydraulic head between static pressure and ground level is often ignored. This also implies that the starting time of the test is not at the static water level. A constant head test, set at ground level, is the other option. However, the decrease in flow rate is not only dependent on the hydraulic properties of the aquifer, but also masked by pipe hydraulic effects within the well. This kind of test would also limit the available drawdown to be utilised for the test. 

Hence,  it was  required  to  develop a method for undertaking hydraulic tests in  strong artesian boreholes allowing for the drawdown to fluctuate between above and below ground and avoiding the pitfalls described above. The solution is a specially designed and constructed well-head for the installation of the pump and monitoring equipment prior to the hydraulic test. The standard tests are slightly modified and will only be carried out after sealing the well-head and reaching static hydraulic pressure. 

The recommended well-head construction and subsequent hydraulic tests were carried out at a strong artesian borehole in the Blossoms Well-field, south of Oudtshoorn in the Western Cape of South Africa.

Abstract

The Fountains East and Fountains West groundwater compartments (by means of the Upper and Lower Fountain springs) have been supplying the City of Pretoria with water since its founding in 1855. These adjacent compartments which are underlain by the Malmani dolomites of the Chuniespoort Group are separated by the Pretoria syenite dyke and are bounded to the north by the rocks of the Pretoria Group (Timeball Hill Formation). Inorganic chemistry data (2007-2012), as well as spring discharge volumes (2011-2012) for the Upper and Lower Fountain springs, supplied by the City of Tshwane Municipality, is being used to characterise the two compartments. This is done by means of piper diagrams, bar graphs and temporal plots. Interpretation of the combined chemical and discharge volume data as well as geotechnical and isotope data (in progress) will aid in understanding  the  karst  aquifer  and  the  controls  on  groundwater  system  within  and  possibly between these compartments.

Abstract

In this study, a petroleum hydrocarbon contamination assessment was conducted at a cluster of petroleum products storage and handling facilities located on the Southern African Indian Ocean coastal zone. The Port Development Company identified the need for the assessment of the soil and groundwater pollution status at the tank farms in order to develop a remediation and management plan to address hydrocarbon related soil and groundwater contamination. Previous work conducted at the site consisted of the drilling and sampling of a limited number of boreholes. The current investigation was triggered by the presence of a free-phase product in the coal-grading tippler pit located ~350 m down gradient and south-east and east of the tank farms, rendering the operation thereof  unsafe.  The  assessment  intended  identifying  the  source  of  product,  distribution  and mobility, the extent of the contamination, and the human health risks associated with the contamination. To achieve these, the investigation comprised site walkover and interviews, drilling of 76 hand auger and 101 direct push holes to facilitate vertical soil profile VOC screening and sampling  (soil  and  groundwater),  as  well  as  granulomeric  analysis  to  understand   grain   size distribution  within  the  soil  profile.  The  highest  concentrations  were  associated with the coarse sand layers with the highest permeability. Free-phase hydrocarbons product was found in holes adjacent to the pipeline responsible for the distribution of the product from the jetty to the different tanks farms. Of the 57 soil samples, 21 had high values of GRO and DRO, with 22 below Detection Limit and 14 can be described having traces of hydrocarbon. Both TAME and MTBE were detected in most of the water samples, including from wells located far down gradient. The groundwater sink, adjacent to the pipeline running from west to east, resulted in the limited lateral spread of MBTE in this area, with limited movement towards the sea. The depth of the soil contamination varies over the sites. Based on the site  assessment  results  it  was  concluded  that  most  of  the groundwater contamination, which is a mixture of different product types, is associated with the pipeline responsible for transporting product from the jetty to the different petroleum companies.

Abstract

After drilling technology improvements in South Africa in the early 1900s, several deep (>300 m) exploratory drilling programmes were conducted to explore for pressurised groundwater resources. The results were not significant, except for the Cretaceous Uitenhage Artesian Basin and recent investigations in folded Table Mountain Group Aquifer systems. Large sedimentary units in Southern Africa do have the structural geometry to drive regional artesian systems; however, diverse climate and aquifer hydraulic limitations counteract these conditions to such a level that sustainable basin- like  deep  flow mechanisms  are  probably  non-existing,  except where enhanced  by  deep mining activities.

On the contrary, several deep drilling projects in South Africa, Botswana and Namibia have undoubtedly  proven  the  existence  of  pressurised  groundwater  strikes  below  300 m  (northern Kalahari)  to  as  deep  as  3 000 m  (western  Karoo  Basin).  Given  the  regional  hydrogeological characteristics of these systems, the availability of sufficient recharge zones required to drive sustainable artesian flow or semiartesian conditions becomes a challenge. The existence of isolated pressurised compartments as a result of the lithostatic pressurisation in the deeper sections of many of the sedimentary successions may prove to be a more realistic explanation for these pressurised water strikes observed during deep drilling operations in Southern Africa.

Abstract

Soil and water pollution are major environmental problem facing many coastal regions of the world due to high population, urbanisation and industrialisation. The hydrofacies and water quality of the coastal plain-sand of part of Eastern Niger-Delta, Nigeria, was investigated in this study. Hydrogeological investigations show that the aquifers in the area are largely unconfined sands with intercalations of gravels, clay and shale which are discontinuous and, however, form semi-confined aquifers  in  some  locations.  Pumping  test  results  show  that  the  transmissivity  ranged  between 152.0 m2/day  and  2 835.0 m2/day  with  an  average  value  of  1 026.0 m2/day,  while  the  specific capacity varied between 828.0 m3/day and 15 314.0 m3/day with a mean value of 6 258.0 m3/day. Well-discharge  ranged  between  1 624.0 m3/day  and  7 216.0 m3/day  with  an  average  value  of 3 218.0 m3/day, while hydraulic conductivity varied between 3.2 m/day and 478.4 m/d with a mean value of 98.6 m/day. These findings indicate that the aquifer in the area is porous, permeable and prolific.

The observed wide ranges and high standard deviations and mean in the geochemical data are evidence that there are substantial differences in the quality/composition of the groundwater within the study area. The plot of the major cations and anions on Piper, Durov, and Scholler diagrams indicated six hydrochemical facies in the area: Na-Cl, Ca-Mg-HCO3, Na-Ca-SO4, Ca-Mg-Cl, Na-Fe-Cl and Na-Fe-Cl-NO3. Heavy metal enrichment index revealed 12 elements in the decreasing order of: Fe > Ni > Cu > Zn > Mn > Cd > V > Co > Pb > Cr > As > Hg. The study identified salt intrusion, high iron content, acid-rain, hydrocarbon pollution, use of agrochemicals, industrial effluents and poor sanitation as contributors to the soil and water deterioration in the area. Saltwater–freshwater interface occurs between 5 m to 185 m, while iron-rich water is found between 20 m to 175 m. The first two factors are natural phenomenon due to the proximity of the aquifer to the ocean and probably downward leaching of marcasite contained in the overlying lithology into the shallow water table, while the last four factors are results of various anthropogenic activities domiciled in the area.

The DRASTICA model, a modification of the DRASTIC model, was developed and used in the construction of the aquifer vulnerability map of the area. Modern sanitary landfill that ensures adequate protection for the soil and groundwater was designed and recommended to replace the existing  open-dumpsites.  Owing  to  the  monumental  and  devastating  effects  of  hydrocarbon pollution in the area, the need to eradicate gas-flaring and minimise oil spills in the area was advocated. Bioremediation and phytoremediation techniques were recommended to be applied in the clean-up of soils and water contaminated with hydrocarbon in the area.

 

Abstract

The aquifer vulnerability of the Molototsi (B81G) and Middle Letaba (B82D) quaternary catchments was assessed to determine the influence of the vadose zone on the groundwater regime. The aquifer vulnerability was assessed by developing a new method, which evaluates the vadose zone as a pathway for pollutants by using the following four parameters: Recharge, Depth to water table, Soil type (saturated vertical hydraulic conductivity) and Slope (RDSS). Recharge was estimated using the Chloride-mass balance method and the depth to the water table was measured in the field using dipmeter. The seepage behaviour (soil type) was determined as hydraulic conductivity from in situ infiltration and percolation testing (SABS 0252-2:1993 and double ring infiltrometer). The slopes were determined with the digital elevation method using ArcGIS software. The four parameters were overlaid using Weighted Sum, Weighted Overlay and Raster Calculator to produce the vulnerability map. Different weightings were attributed in the methods and the best selected. The results obtained indicated high vulnerability on the lower and upper parts of both catchments. Aquifers in areas which showed high vulnerability are at high risk of contamination. The benefits of the  method  described  are  (a) the  easy  quantification  of  the  parameters  through  fairly  simple methods and (b) the exclusion of arbitrary index values.

Abstract

Southern Africa hosts over 93% of the continent's energy, which has been conserved in coal seams deposited  in  various  Karoo  age  sedimentary  basins.  Carbon  dioxide  geological  storage  (CGS)  is proving  to  be  an  emerging  greenhouse  gas  technology  (GHGT),  that  global  governments  have elected to mitigate the projected coal use in Southern Africa. One of the major challenges of successfully introducing CGS to the public and world leaders is the significant risk the technology poses to groundwater resources. Lack of public confidence is further coupled by the poor knowledge of the subsurface behaviour of injected media, such as CO2, in South African potential lithological reservoirs. The study has utilised data from a current MSc research, in which the Springbok Flats Coal Basin (SFCB) has been used as the problem set-up. The aim of this study is to determine which FELOW™ mesh  geometry would  be  the most  suitable  to  simulate  a  CO2   ingress plume within  a regional aquifer. The study has utilised principals of dense vegetation zones (DVZ) and density- variable fluid flow (DVFF) when simulating the ingression. The specific objective is to utilise the simulation  results  to  guide  amendments  of  water  legislature,  towards  accommodating  CO2 geological  injection  and  storage operations.  Results indicate  that  a  combination  of  high-quality triangular meshes of various geometries, created with the FEFLOW compatible mesh generator, TRIANGLE, produced the best 3D model and simulation results. The basic matrice unit for the DTZ was defined as a quad mesh composed of two right-angled triangles and one equi-angualar triangle (five nodes), while the unit for modelling springs was defined as a quad mesh with four-equi-angular triangles, both used in various scales. The results were used to amend the Stream Flow Reduction Activities (SFRA) policy and thus the aquifer licensing procedure of the National Water Act, in order to accommodate the allocation of aquifer use licenses for CO2  geological storage operations. The amendments illustrate the significance of finite element simulation codes for integrated water resources management policy.

Abstract

An understanding of the movement of moisture fluxes in the unsaturated zone of waste disposal sites play a critical role in terms of potential groundwater contamination. Increasing attention is being given to the unsaturated or vadose zone where much of the subsurface contamination originates, passes through, or can be eliminated before it contaminates surface and subsurface water resources. As the transport of contaminants is closely linked with the water flux through the unsaturated zone,  any quantitative analysis of contaminant transport must first evaluate water fluxes into and through this region. Mathematical models have often been used as critical tools for the optimal quantification of site-specific subsurface water flow and solute transport processes so as to  enable  the  implementation of management practices that minimize  both surface water  and groundwater pollution. For instance, numerical models have been used in the simulation of water and solute movement in the subsurface for a variety of applications, including the characterisation of unsaturated zone solute transport in waste disposal sites and landfills. In this study, HYDRUS 2D numerical simulation was used to simulate water and salt movement in the unsaturated zone at a dry coal ash disposal site in Mpumalanga, South Africa. The main objective of this work was to determine the flux dynamics within the unsaturated zone of the coal ash medium, so as to develop a conceptual model  that  explains  solute  transport through  the unsaturated  zone  of the coal ash medium for a period of approximately 10 year intervals. Field experiments were carried out to determine the model input parameters and the initial conditions, through the determination of average moisture content, average bulk density and the saturated hydraulic conductivity of the medium. A two-dimensional finite-element mesh of 100 m × 45 m model was used to represent cross  section  of  the  ash  dump.  Two-dimensional  time  lapse  models  showing  the  migration  of moisture fluxes and salt plumes were produced for the coal ash medium. An explanation on the variation of moisture content and cumulative fluxes in the ash dump was done with reference to pre-existing ash dump data, as well as the soil physical characteristics of the ash medium.

Abstract

The occurrence of groundwater around a mined-out open pit, connected to an active underground working is not completely understood, but it is fascinating. It has been established that gold mineralisation in study area was structurally controlled. The geomorphology of the local drainage system is highly controlled by the fold or fault architecture. Surface water flowed through, and eroded open fractures in exposed damaged zones (zone of subsidiary structures surrounding a fault). Previous  conceptual  hydrogeological models  of  groundwater  system  suggested  is  a  two-aquifer system, consisting of a fractured aquifer overlain by a weathered aquifer, where groundwater flow mimics surface topography. Based on recent drilling and reassessment of historic geological and hydrogeological data, the groundwater system around the mine could not only be described in terms of an elevation or stratigraphic units, as traditional aquifers are. The weight of the study was placed on accurately understanding the groundwater system in the deposit area by using structural hydrogeology as a best tool in the hydrogeological tool box. From a hydraulic head point of view, in addition to the weathered groundwater system, there are as many bedrock aquifers and aquitards as there are major structures in the pit area.

Abstract

The key towards modern groundwater management lies in a profound strategy from monitoring data collection over data processing and information management to clear reporting on the development of groundwater resources. Only thus planners are enabled to take informed decisions towards sustainable use and well-keeping of available groundwater. A core in this strategy is the digital database in which all relevant data and information is stored, handled and displayed. It is thus that the Namibian Ministry of Agriculture, Water and Forestry (MAWF) decided to replace within the activities of the Namibian–German cooperation project “Groundwater for the north of Namibia”, the existing national groundwater database GROWAS with the completely new development of the GROWAS II  version.  Through  the  experience  of  the  project  partner  BGR  (Federal  Institute  for Geosciences and Natural Resources) the focus was put on the critical issue of data quality control. As the analysis of the old system indicated unclear data operation procedures as a major source of errors, improved user-friendliness was high on the agenda for the new database. Developed closely to  the  needs  of  Namibian  Water  Authorities,  GROWAS II  features  a  GIS-based  graphical  user interface (GUI) with a vast range of query functions, a modular system including time series tools, hydrochemistry, licenses for abstraction application and groundwater status reporting functions, among others. Quality control is secured through different measures like the “fosterage” option which allows the input of data into a temporary status with restricted access until released by senior experts, the quick and direct interaction with Google Earth to verify locations and the extensive use of look-up tables and descriptive keys in alignment with other regional geo-databases. Furthermore, data entries can be marked according to their estimated reliability with traffic light coding. These measures should ensure that only good quality data will be added in the future. Upcoming development steps are the practical tests of the single modules in day-to-day use, the integration into or exchange with other information systems and the improvement of older existing data as far as possible. Namibia will thus be better prepared for future groundwater challenges.

Abstract

A new mining site situated near Kolwezi in the Democratic Republic of the Congo plans to develop a pit in phases over a period of six years. The mine requires dewatering volume estimates of the pit as well as a constant water supply to the plant. Hydrogeologic data available at the site during the scoping phase was limited to a few water level measurements and blowout yields from only five hydrological boreholes. Hydraulic properties from reports at neighbouring sites were extrapolated to the geological units at the site. The depth to water level at the site is about 20 m, with a planned final pit depth of approximately 180 m below surface.

Based on the limited data available an analytical approach to estimate the inflow into the mine was adopted. Analytical calculations proposed by Marinelli and Niccoli (2000) were used to estimate the inflow into the Pumpi mine pits. The analytical calculations consider recharge, depth of mining vertical and horizontal hydraulic conductivities. Drawdown evolution of pit dewatering are obtained by using different mining depths at different mine stages. The output results from the analytical calculations are the maximum extent of influence of the pit as well as the volume of water inflow into the pit. Limitations of the analytical equations are that they, amongst others, cannot consider complex boundaries.

Drilling and pump testing to obtain local hydraulic properties and boundary conditions are planned during the first quarter of 2013. The numerical model will be set up after the drilling and pumping tests, using the new data for calibration. The numerical model will contain as much of the physical layer definitions and potential internal boundaries as possible with model boundaries incorporated along  far  field  fault  zones  and  hydraulic  boundaries.  The  numerical model  should  improve the reliability of estimates of pit inflow and water supply to the plant.

The results between the analytical and numerical approaches can then be compared to improve future dewatering estimates with limited data. It is expected that the reliability of the analytical predictions will reduce after year 4, where the role of boundaries are expected to influence the drawdowns and related flow towards the pit.

Abstract

Ladismith was established in 1851 where freshwater discharge from the Klein Swartberg Mountains. Growth of the town required building of the Goewerments Dam in 1920 and the Jan F le Grange Dam in 1978. However, water demand now matches supply, and water shortages are being experienced. Poor management and recent droughts exacerbated the situation. A project was initiated to address shortcomings with the existing supply and identify additional sources of water. Groundwater is an obvious option, with the regionally extensive Cango Fault located directly north of  the  town.  The  west-east  trending  fault  juxtaposes  highly  productive  Table  Mountain  Group Aquifers with less productive argillaceous rocks of the lower Witteberg Group. The Alluvial Aquifer is also a target, with a recently drilled DWA monitoring borehole reported to be high-yielding. Drilling and testing of three exploration boreholes drilled into the fault, returned lower than expected borehole  yields,  but  still sufficient  to  contribute  to  the  town’s water  supply  and  merit  further exploration. Boreholes drilled north of Ladismith could be used to increase the existing water supply by 50%.

Abstract

The so-called apparent increase of transmisivity (T) or hydraulic conductivity (K) with scale is an artifact and does not exist in the field. The reason for the apparent increase of T with scale is due to the use of the “not applicable” random log Gaussian stochastic models that are used by geohydrologists. In the petroleum field, where deterministic methods are applied, the apparent increase of T with aquifer volume does not occur. Groundwater practitioners have to change their view and use models that do not show this effect.

Abstract

Quantification of hydrological processes is required for many projects related to potential groundwater recharge. Thus, investigation on various hydrogeologic conditions is paramount. Changes of climate can affect the hydrological cycle by altering groundwater recharge. As a result, an understanding of the hydrological conditions is essential to make sensible predictions of the possible groundwater recharge. Thus WetSpass, which yields spatially varying groundwater recharge using hydrological inputs, can be used together with a geographical information system to quantify the environmentally acceptable flow regime of the catchment area. This paper presents an overview on the use of WetSpass in combination with GIS on quantification of groundwater potential which will assist to sustainable groundwater development in the catchment area. Previous applications are presented.

Abstract

The subject mine has a policy of avoiding groundwater inflow into the underground workings due to the impact on the mine operations. It has already implemented a significant mitigation measure by excluding shallow mining and a large pillar under the river that is present in the mining area. To assess the potential for groundwater inflows into the underground mine workings as a result of a planned expansion project, Environmental Resources Management (ERM) undertook numerical groundwater modelling based on a detailed geological investigation to define the proposed mining area into high, medium and low mining risk areas with respect to potential groundwater inflow. The conceptual definitions of the mining risk areas are: 

High Risk general groundwater seepage and inflow expected in the face and roof of the mining unit from numerous joints and fractures which is regarded as serious enough to permanently halt mining operations. 

Medium Risk possibility of limited point source groundwater inflow in the face and roof of the mining unit from sporadic selective joints and fractures. Not expected to halt mining operations. 

Low Risk no significant groundwater risk to mining operations expected.

The areas identified as being potentially at risk from groundwater inflow were determined using a combination of geological mapping, ground geophysics and percussion drilling that was incorporated into a numerical hydrogeological model. The study undertaken by ERM enabled the mine to incorporate the identified mining risk zones into the early stages of the mine planning, and allowed for a significant reduction in the size of the safety pillar under the river.

Abstract

Determining   impacts   associated   with   the   production   of   shale   gas   in   the   semi-arid   Karoo   on groundwater is vital to people living in the Karoo. On the one hand shale gas can be a game-changer for energy supply, but on the other it may have a devastating effect on the environment. Knowing the potential  impacts  of  shale  gas  mining  beforehand,  the  government  can  set  appropriate  regulatory protocols  and  tools  in  place  to mitigate  potential  risks.  This paper  describes research  done  on  the potential impact that hydraulic fracturing could have on groundwater in the Karoo. A wild card that only exists in the Karoo Basin of South Africa is the numerous dolerite intrusions. These dolerite structures are associated with relative high-yielding boreholes because of the fractured contact aureole that exist between solid dolerite and the adjacent Karoo sediments. Compromised cement annuli of gas wells are the  major  preferential  flow  paths along which  methane  and fracking fluid  can escape  into shallow, freshwater aquifers. This study focused solely on the impact of compromised cement annuli of gas wells. The Karoo Basin is under artesian conditions which imply that any pollutant will always try to migrate upwards in the Karoo. The hot-water springs in the Karoo indicate that upward velocities of water are relatively high (the spring water take only days to travel from deep down to the surface). The cubic law was  used  to  estimate  potential  upward  leakage  rates  from  gas  wells  (during  production,  but  after cessation thereof as well, when pressures will rebuild  because  of  artesian  behaviour  of  the  Karoo formations).  Potential  leakage  rates  along  faulty annuli of a well can vary between a value close to zero to two liters per second in the case of an aperture of 0,5 mm. These leakage rates were used as input to a 2D numerical groundwater flow and mass transport model. The 2D model was run for 30 years and the movement of pollution from the gas wells on the pad simulated. The model indicates that an area of 300 ha could be contaminated over a period of 30 years in a downstream groundwater flow direction.  If  an  abstraction  borehole  drilled  along  a  fault  zone  or  a  dyke,  intersecting  the  fracked reservoir, is introduced into the model, results predict that the pollutant will reach the borehole in less than two months if the borehole is situated six kilometres from the well-pad. The total impact that fracking will have on the groundwater in the Karoo, is a function of the total area that will be fracked.

The outcomes of this research clearly show that fracking in South Africa cannot be done in the same way than  it  is  currently  done  worldwide.  A  rule  that  will  force  gas  companies  to  disclose  fracking  fluid contents is non-negotiable. Companies should also be required to measure pressures in the fracked gas reservoir after closure. An additional requirement to enforce sealing of the entire fracked reservoir with a very dense material like bentonite or a mud with a very high density to capture the fracking fluids deep down in the gas reservoir should not be negotiable.

Abstract

Flowing fluid electrical conductivity (FFEC) profiling provides a simple and inexpensive way to characterise a borehole with regards to the vertical location of transmissive zones, the hydraulic properties  of  the  various  transmissive  zones  and  the  intra-well  flow  conditions  which  may  be present in the well under ambient conditions. The method essentially involves analysing the time evolution of fluid electrical conductivities in a borehole under pumped and ambient conditions using a down-hole conductivity/temperature data logger. The premise of the method is that the borehole column of water has its electrical conductivity altered by adding saline water into the borehole. This results in a contrast in electrical conductivity (EC) between the water in the borehole and the water in the adjacent formation. At depths where transmissive zones are present, decreases in EC values in the FFEC profile will be observed where formation water with a lower EC (relative to the borehole water column) enters into the well, whilst pumping at low abstraction rates (between 500 ml and 1 liter per minute). By altering the EC of the well-borewater and maintaining a constant pumping rate,  the  sequence  of  FFEC  profiles  depicts  the  dynamic  flow  and  transport  response which  is dependent upon the hydraulic properties of the formation. In this paper the authors present several examples where FFEC profiling has been used to identify transmissive zones in boreholes where no information existed with regards to the vertical distribution of transmissive zones. Furthermore, the authors present case studies where FFEC profiling has been employed as an alternative technology to more conventional hydraulic profiling techniques. This includes a comparative technology case study where down-hole impeller flow meter technology was employed in addition to FFEC profiling and a multi-rate FFEC profile test which was used to determine discrete fracture transmissivity values in a borehole where packer testing equipment could not be installed. Within the context of groundwater contamination investigations, the method holds several attractions as it generates minimal waste water to be managed and disposed of, is inexpensive and can be completed within a relatively short time period.

Abstract

The thermal springs of Swaziland and adjacent KwaZulu-Natal have, over the years, attracted attention from hydrogeologists, hydrochemists and structural geologists. While some of the springs in Swaziland are well known amenities, others are less well-visited and some difficult to access. There are eleven warm springs in Swaziland, discharging between 1 and 10 l/s from Precambrian age rocks; all are situated at or near valley bottoms. The springs have surface discharge temperatures of between 25 and 52 oC and total dissolved solids concentrations of less than 400 mg/l. In all cases the water is meteoric in origin. Geothermometry indicates that maximum temperatures up to 100 oC are achieved during circulation. If the average geothermal gradient is about 20 oC/km as recorded in a deep mine at Barberton, then this would require circulation up to a depth of several kilometres. However, it is likely that circulation bottoms at about 1 km, as pressure of overburden inhibits dilation of fractures at such depths, and the excess temperature may derive from a locally enhanced geothermal gradient. The discharge water is young, with 14C ages of between 4 000 and 5 000 years.

Abstract

The effluent at the eMalahleni water reclamation plant is being processed through reverse osmosis which improves the quality of the mine water to potable standards. Brine ponds are generally used for inland brine disposal and this option has been selected for the eMalahleni plant. Limited capacity to store the brines requires enhanced evaporation rates and increased efficiency of the ponds. This study aims to establish the physical behaviour of the brine from the eMalahleni plant in an artificial evaporation environment. This includes the actual brine and synthetic salts based on the major components.

An experimental unit was designed to accommodate and manipulate the parameters that affect the evaporation rate of brines and distilled water under certain scenarios. Two containers, the one filled with 0.5M of NaCl and the other with distilled water were subjected to the same environmental conditions in each experimental cycle. Each container had an area of a 0.25 m² and was fitted with identical sensors and datalogger to record the parameter changes. The energy input was provided by infra-red lights and wind-aided electrical fans. This equipment used in these experiments was to simulate actual physical environmental conditions. 

The rate of evaporation was expected to be a function of humidity, wind, radiation, salinity and temperature. The experiments showed the type of salt and thermo-stratification of the pond to be significant contributors to the evaporation rate. The results also showed that the NaCl solution absorbed more heat than the water system. The difference in evaporation observed was ascribed to a difference in the heat transfer rate, which resulted in a higher temperature overall in the brine container than in the water container under similar applied conditions. This effect remained despite the introduction of 2 m/s wind flow over the tanks as an additional parameter. The wind factor seemed to delay evaporation due to its chilling effect upon the upper layers of the ponds, initially hindering the effective transfer of radiative heat into the ponds.

 

Abstract

The  possible  future  exploitation  of  methane  in  the  Karoo  has  stimulated  work  from  various disciplines to examine its occurrence, exploitability and exploitation risks. Groundwater issues are vital in this context because of its possible use during exploration and exploitation, and more important, to understand the risks of its pollution during and after all these activities. This paper presents the experiences of the authors to document the presence of methane in the Karoo based on data from boreholes, springs, tunneling and deep drilling. There have been frequent anecdotal reports of explosive gas in boreholes, both dry and wet, in the Karoo. In some cases the gas is identified as methane. Thermal spring waters in the Karoo invariably contain some amounts of methane. Methane pockets have been found in the Karoo during tunneling projects and in some deep Soekor boreholes. A groundwater study in the vicinity of the Gariep Dam indicated substantial quantities of methane in warm groundwater and an association with helium. The isotope concentrations of carbon and hydrogen in methane characterise the methane-forming processes. Such analyses in samples from the central Karoo basin are consistent with that of thermogenic gas found  elsewhere  in  the  world.  Towards  the  edges  of  the  basin,  lower  13C-values  indicate  that methane  there  is  produced  by  microbial  processes  at  shallower  depths.  The  presence  of thermogenic methane together with helium on the surface is likely to give clues to pathways from depth.

Abstract

POSTER Lake Kosi Bay is an estuary-linked lake system composed of four interconnected lakes, namely Makhawulani , Mpungwini , Nhlange , Amanzamnyama and interconnecting channels, which drains via a sandy opening to the Indian ocean and three extensive areas of swamps (Wright 2002 ). The Kosi Bay lake system is considered as the most pristine lake system on the South African coast and has been used as a recreational fishing destination since 1950 (James et al. 2001). The lakes are separated from the ocean by a strip of forested sand dunes (South African Wetlands Conservation Programme 1999;  Wright  2002).  Groundwater  utilisation  in  the  area  ranges from  extraction  of seasonal groundwater from shallow, hand-dug wells to drilling of boreholes for family or communal use and development of groundwater well-fields for agricultural projects (Botha et al. 2012). The exact amount of abstraction of the groundwater is unknown. 

The  Kosi  Bay  system  is  situated  on  the  northern  KwaZulu-Natal  coast,  2.9 km  south  of  the Mozambique international boarder. According to a Statistics South Africa survey (2007), the approximate  population  is  163 694.  The  Kosi  system  falls  under  the  UMkhanyakude  District Municipality, which covers more than 128 818 km2. The travelling distance from north of Durban is 470 km and coordinates of the Kosi Bay system are 2650S-2711S, 3238E- 3253 (Write et al. 1997). The catchment has an area of about 304 km2. The Kosi Bay system is principally clean, white sands, particularly in the northern most reaches where tidal influences are most marked and the system experiences a seasonal inflow of fresh water into its heard (Andeas Holbach 2012).